7.21  Spare Parts and Ancillary Items
The following replaceable parts are available for the Galaxy 65 Subsystem:
 
7.22 Upgrading Your LRC I/O Modules
You can upgrade your existing JBOD or RAID LRC module to a Rorke Data Galaxy 65 RAID LRC module 
in accordance with the following procedure: 
Caution
Ensure that your Power Supply/Cooling modules are marked with P/N 44191-XX. If they are not you will 
need to upgrade your PSUs. Please contact your supplier and request the upgrade modules.
1
Change the Ops Panel switch settings to those shown in 
Table 7–9
.
Important
Switch settings are only read at Power On.
The Galaxy 65 enclosure ID must always be set to select ID1.
2
Remove the existing LRC modules in accordance with the procedure in 
7.12.3.1, ”Removing the Module”, 
on page 72
.
3
Install the Storage Manager modules in accordance with the procedure in 
7.12.3.2, ”Inserting the 
Module”, on page 73
.
• Chassis (including Backplane)
– RS232 cable
• AC Power Supply/Cooling Module
– LAN cable
• Drive Carrier Module
• 19 inch rack mounting rail kit
• Storage Manager Module
• Dummy Carrier Module
• External FC-AL Signal Cables
• Blank SM Module
• Cables
• SFP module, optical
– LC - LC optical cable
• SFP module, copper
– LC - SC optical cable
• Battery, Li-ion 
– SFP - SFP copper patch cable (1 M length)
• (Country specific) power cords 
– HSSDC2 - HSSDC1
• Bifurcated power cords
– HSSDC2 - DB9
• Keys for Drive Carrier modules.
– HSSDC2 - HSSDC2
• All documentation