Emerson Liebert DS Precision Cooling System 28-105kW Data Sheet

Page of 24
INFRASTRUCTURE 
MANAGEMENT
Improving performance 
of the IT infrastructure 
and environment
ECO AVAILABILITY
Balancing high levels of 
availability and efficiency
FLEX CAPACITY
Adapting to IT changes for 
continuous optimization 
and design flexibility
HIGH DENSITY
Delivering architectures 
from 10–60 kW/Rack to 
minimize space and cost
A Tradition Of Reliability You Can Count On
Liebert Precision Cooling equipment is the 
standard by which all others are judged. 
The number of units that are in the fi eld 
far exceeds the combined number of all 
other brands. Nine out of ten Fortune 500 
Companies use Liebert cooling systems.
Liebert Precision Cooling Systems are used 
in the most demanding, critical applications 
in the world. From banking to government 
to corporate computer and communications 
centers, when it has to be the best—this is 
the brand of choice.
2
For sensitive electronics, environmental 
control is more than simple cooling. 
“Comfort” air conditioning systems are 
designed to cool people and office space. 
They simply cannot provide the kind of 
environment required by high performance 
computer or communication equipment.
Why You Can’t Take Chances When 
Cooling Your Critical Space
Standard building cooling systems are designed 
to keep people comfortable 8-12 hours each 
day from spring to autumn with no provision 
for winter operation. A precision cooling system 
is designed to operate over a wide range of 
ambient temperatures from as low as -30°F 
(-34.4°C) up to 120°F (48.9°C).
Sensitive electronics must be maintained in a 
stable environment of 64.4°F to 80.6°F (18°C to 
27°C) with moisture between 41.9°F (5.5°C) dew 
point and 60% relative humidity with 59°F (15°C) 
dew point. Computers and communications 
equipment generate six to ten times the 
heat density of normal offi ce space, the air 
conditioning system must have more than just 
enough cooling capacity.
 It must have the precision to react quickly to 
a drastic change in heat load and prevent wide 
temperature fluctuations—something a large 
building HVAC system cannot do.
Emerson Network Power Understands The Need For 
Precision And Reliability...
And Why This Is So Important To You
Liebert DS Is Ideally Suited For:
  Data Centers
  Computer Rooms
  Network Operations 
Centers
  Telecom/CATV
  Labs And Testing
  Production Facilities
Liebert
®
 DS 
TM
 delivers Effi ciency Without Compromise 
TM
Efficiency Without Compromise provides a path to optimize data center infrastructure around design, operating and 
management efficiencies – while maintaining or improving availability. This is achieved through the proper selection and 
utilization of cooling, power and monitoring technologies, supported by key services and local expertise.