EarthQuake W1200 User Manual

Page of 16
Operator's Manual
5-Ton Electric Log Splitter W1200
Check for parts online at 
www.getearthquake.com or call 800-345-6007 M-F 8-5
9
MAINTENANCE
REpLACING HYDRAULIC OIL
Replace the hydraulic oil in the log splitter after every 150 
hours of use. Take the following steps to replace the oil.
1.  Make sure all moving parts are stopped and the log split-
ter is unplugged.
2.  Remove oil drain bolt and dipstick. Make sure bleed screw 
is closed tight.  (SEE FIGURE 9)
3.  Turn the log splitter on the support leg side over using a 
one gallon or larger capacity container to drain the hy-
draulic oil.  (SEE FIGURE 10)
4.  Turn the log splitter on the motor side.  
(SEE FIGURE 11)
5.  Refill with 3.75 quarts of fresh hydraulic oil.
6.  While keeping the log splitter vertical, clean the surface 
of dipstick on the oil drain bolt and put it back into the oil 
tank.
7.  Make sure the level of the refilled oil is between the two 
grooves around the dipstick.
8.  Clean the oil drain bolt before re-threading it back in. 
Make sure the bolt is tightened to avoid leakage before 
placing the log splitter horizontally.  
IMpORTANT: LOOSEN bLEED SCREw 3-4 TURNS bEFORE 
OpERATION.
Periodically check oil level to ensure it is between the two 
grooves around the dipstick. If the level is below the lower 
limit, fill until level is correct.
The following hydraulic oils, or equivalent, are recommended 
for the log splitter’s hydraulic pump:
SHELL Tellus 22
MOBIL DTE 11
ARA Vitam GF 22
BP Energol HLP-HM 22 
SHARpENING wEDGE
When the log splitter wedge becomes dull and/or worn, 
sharpen the wedge using a fine-toothed file and smooth any 
burrs or crushed areas along the cutting edge.
oil drain container
Figure 10
Figure 11
oil drain 
plug
dipstick
bleed screw
Figure 9
full mark