HDC II Programming Guide
Set up a Hot Drink
July, 2003
38
6730018
VIEW OR SET THE HOT WATER TANK 
TEMPERATURE
1.
Press 
 then 
 until the display shows 
pbq=OMO=°c=
.  In this 
example, 202° is the water tank temperature setpoint in degrees Fahrenheit.  
If a decimal point appears next to the "F", the heater is on.
2.
If desired, enter a new setpoint in the accepted range of  149° - 205° F (65° 
- 96° C).
NOTE
The lower limit for vending is 20° below setpoint, up to a max-
imum of 180° F (82° C).
3.
To change display units (replace the "F" with a "C" for Celsius), press 
.
4.
CONTINUE.
SET UP LOW TEMPERATURE DISPENSING
1.
Press 
 then press 
 until the screen displays either
a.
LTDIS OFF.  This causes the machine to operate the same as the previous 
Hot Drink Center.  For example, with a setpoint temperature of 202º F 
the machine will inhibit vending when the water tank temperature falls 
below 182º F.
- OR -
b.
LTDIS ON.  Allows vending to a water tank temperature of 140º F.
2.
Press 
 to change between 
ON and OFF.
3.
CONTINUE.