Fujitsu MAN3367 User Manual

Page of 302
C141-E124-01EN
3 - 54
Page Code
Description
Changable Parameter
01
Buffer Overrun / Underrun Page
Disable
02
Write Error Counter Page
Enable
03
Read Error Counter Page
Enable
05
Verify Error Counter Page
Enable
06
Non-medium Error Page
Enable
0D
Tempature Page
Disable
0E
Start-stop Cycle Counter Page
Enable only 0002
0F
Application Client Log Page
Enable
10
Self-Test Result Log Page
Disable
(2)
Page length
This field specifies the length in bytes of the following log parameters. If the application client
sends a page length that results in the truncation of any parameter, the device server terminates the
command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in
paramter list [=26-00]).
The log pages contain one or more special data structures called log parameters as shown below. Each log
paramter begins with a 4-byte parameter header followed by one or more bytes of "Parameter Value" data.
         Bit
Byte
7
6
5
4
3
2
1
0
0
Parameter Code (MSB)
1
Parameter Code (LSB)
2
DU
DS
TSD
ETC
TMC
LBIN
LP
3
Parameter Length
4
n
        Parameter Value
(1)
Paramter code
This field identifies the log paramter being transferred for that log page.
~
~
~