Fujitsu MAN3367 User Manual

Page of 302
C141-E124-01EN
3 - 103
The “Transfer byte length” field in the CDB specifies the defect data length (number of bytes) that
can be received by the INIT.  The IDD terminates data transfer when transfer of the length of
defect data specified in the “Transfer byte length” field is completed or when transfer of all the
defect data of the specified type is completed.  Also, when zero is specified in the “Transfer byte
length” field, this command is terminated without execution of data transfer.
Figure 3.17 shows the format of defect data transferred to the INIT by this command.
                     Bit
Byte
7
6
5
4
3
2
1
0
0
X‘00’
1
0
0
0
PList
GList
Defect List Format
2
Defect List Length (MSB)
3
Defect List Length (LSB)
4
Defect Data
n
Figure 3.17 READ DEFECT DATA command:  Defect data configuration
~
~
~
~
Header
Defect
Descriptor
List
~
~