 2. 
Troubleshooting
“SYSTEM ERROR: xx” 
occurs.
The following causes are probable, depending 
on the symptoms.
1) Turning the power off and back on corrects 
the error.

Communication failed because of improper 
timing.
1) If communication is stable after turning the 
power on again, continue and observe 
operation.
2) Turning the power off and back on does not 
correct the error.

A certain condition always causes the error.  
Or the POD is faulty.
2) Make a note of the information on error 
number, etc. displayed on the screen and 
contact your local distributor.
3) A CF card is inserted.

The CF card (front and back) may be 
reversed.
If none of the above matches your error, 
contact your local distributor.
3) Check that the inserted CF card faces the 
correct side.
Switches do not work.
1) Switches do not work in the RUN mode.  A 
beep sounds.

Is the switch interlock enabled?
1) Check the settings of switch functions, etc. 
on the editor.
2) Switch activation position is wrong.
On the “I/O Test” screen displayed from the 
Main Menu screen, press the [Switch 
Check] switch.  On the touch switch test 
screen, a position different from the 
pressed position is activated.

The switch activation position may be 
misaligned.
2) Perform a touch switch adjustment (page 
3) Switches do not work even in the STOP 
mode.
On the “I/O Test” screen displayed from the 
Main Menu screen, press the [Switch 
Check] switch.  When the touch switch test 
screen is pressed, nowhere is activated.

POD switches may be faulty.
3) Return the POD to your local distributor.
The screen becomes dark or 
black.
1) Touching the screen restores it to the 
previous illuminated state.

The backlight operates automatically as 
preset.
1) The time for turning off the backlight can be 
changed on the editor.
2) Touching the screen does not restore it.  
However, the POWER lamp is lit.

The backlight may be at the end of its life.  
Or the POD may be faulty.
2) Return the POD to your local distributor.
Symptom
Cause
Solution
SYSTEM ERROR : XX
TEA : XXXXXXXX
SSR : XXXXXXXX
R0 : XXXXXXXX
R2 : XXXXXXXX
R4 : XXXXXXXX
R6 : XXXXXXXX
R8 : XXXXXXXX
R10 : XXXXXXXX
R12 : XXXXXXXX
R14 : XXXXXXXX
EXPEVT : XXXXXXXX
SPC : XXXXXXXX
R1 : XXXXXXXX
R3 : XXXXXXXX
R5 : XXXXXXXX
R7 : XXXXXXXX
R9 : XXXXXXXX
R11 : XXXXXXXX
R13 : XXXXXXXX
R15 : XXXXXXXX