When bit number N in the RSM is set, the receive sequence is as usual: data which is shifted into the 
enabled receivers shift registers is transferred to the receive data registers and the RDF flag is set.
Data written to the RSM affects the next received frame. The frame being received is not affected by this 
data and would comply to the last RSM setting. Data read from RSM returns the last written data.
After hardware or software reset, the RSM register is preset to $FFFFFFFF, which means that all 32 
possible slots are enabled for data reception.
NOTE
When operating in normal mode, bit 0 of the mask register must be set to 
one, otherwise no input is received.
6.4
Operating Modes
ESAI operating mode are selected by the ESAI control registers (TCCR, TCR, RCCR, RCR and SAICR). 
The main operating mode are described in the following paragraphs.
6.4.1
ESAI After Reset
Hardware or software reset clears the port control register bits and the port direction control register bits, 
which configure all ESAI I/O pins as disconnected. The ESAI is in the individual reset state while all ESAI 
pins are programmed as GPIO or disconnected, and is active only if at least one of the ESAI I/O pins is 
programmed as an ESAI pin.
6.4.2
ESAI Initialization
The correct way to initialize the ESAI is as follows:
1. Hardware, software, ESAI individual, or STOP reset.
2. Program ESAI control and time slot registers.
3. Write data to all the enabled transmitters.
4. Configure at least one pin as ESAI pin.
During program execution, all ESAI pins may be defined as GPIO or disconnected, causing the ESAI to 
stop serial activity and enter the individual reset state. All status bits of the interface are set to their reset 
state; however, the control bits are not affected. This procedure allows the DSP programmer to reset the 
ESAI separately from the other internal peripherals. During individual reset, internal DMA accesses to the 
data registers of the ESAI are not valid and data read is undefined.
The DSP programmer must use an individual ESAI reset when changing the ESAI control registers (except 
for TEIE, REIE, TLIE, RLIE, TIE, RIE, TE0-TE5, RE0-RE3) to ensure proper operation of the interface.