31. Move the crankshaft to one side of the 
power frame using a light tap from a 
rubber mallet or a pry bar.  Rotate the 
crankshaft several turns and repeat the 
light taps from a rubber mallet or the use 
of a pry bar to insure the crankshaft is to 
one side. 
 
 
32. Mount indicator base on the power 
frame with the indicator tip on a 
machined shoulder surface of the 
crankshaft (do not measure from a cast 
surface) and the axis of the indicator 
parallel to the crankshaft. 
33. Set the dial indicator to zero. 
 
34. Move the crankshaft back over to the 
opposite side and read bearing endplay 
as total indicator movement.  Rotate the 
crankshaft several turns and repeat the 
effort to move the crankshaft in the 
direction described in this step.  Repeat 
the dial indicator measurement.  
Remove or add shims as necessary to 
achieve proper endplay (.002” tight to 
.003” loose).  Distribute shims equally 
on both bearing housings.  Verify the 
endplay with the dial indicator per this 
procedure described before final 
assembly. 
35. Install the oil seal (19) into the bearing housing.  The oil seal can be installed with 
light hammer blows.  When properly seated it will be flush with the face of the 
bearing housing. 
36. Install the piston rod seal holder (9) and seal retainer (8) in the power frame per 
instructions in section 9.4.1.  The crankshaft should turn freely. 
37. Complete reassembly of pump. 
38. Torque all fasteners as outlined in Fastener Torque Requirements, Section 11.0 
of this manual.