Clover Electronics C12E User Manual

Page of 10
8

thermostat may be defective. 
Replace the thermostat. 
The thermostat is improperly set for the 
prevailing environmental conditions and 
cooler usage. 
Adjust the thermostat. 
short running cycle. It 
is cooling, but does not 
run long enough to 
cool water to the 
required level. 
The compressor motor is defective, 
causing the cooler to cycle on the overload 
protector. 
Replace the compressor. 
Return cooler to authorized service center 
or factory for repair. 
F. A. The cold water 
flows slowly or not at 
all. 
The cold water thermostat is so much low, 
causing ice to build up in the reservoir, 
blocking water flow. 
Defrost cooler. 
Adjust the temperature control. 
NOISE
 
The  cooler  is  not  level. 
The  cooler  must  be  leveled. 
Place  the  cooler  on  even  surface. 
A  section  of  the  tubing  inside  the 
cooler  is  touching  other  parts  of  cooler, 
causing  noise  to  be  generated  due  to 
vibration. 
Adjust  position  of  the  tubing  to  make 
sure  it  is  not  in  contact  with  any  other 
parts. 
Check  the  connection  of  the  fixed 
screws. 
Completely  connect  the  fixed  screws. 
A.  There  is 
excessive  noise 
coming  from  the 
cooler,  but  it  is 
otherwise  operating 
normally. 
The  compressor's  operation  is  noisy 
because  of  inherent  conditions. 
Advise  the  customer  of  the  cooler's 
normal  operating  sounds. 
WATER  LEAKAGE
 
A.  Leakage  through 
inside  of  appliance 
The  cold  water  tank  leaks. 
Return  chiller  to  authorized  service 
center  or  factory  for  repair. 
OTHERS 
Mineral concentration of supplied water is 
somewhat high. 
This product does not include filters. 
Change the existing filter or use a proper 
one. 
A.  Odd  taste  and 
smell  in  Water 
No use for a long time. 
Continue to let the water flow until it runs 
clear. 
When using a water pressure regulator. 
Adjust a regulator according to it’ manual or 
contact a qualified engineer. 
B.  Strong  water  flow 
Supplied water pressure is set up too high 
originally. 
Install a regulator that can control the 
pressure or contact a qualified engineer.