7
 
PLC Fault Table Descriptions (Continued)
PLC Fault
User Action
LAN I/F can’t init - check parms; running soft
Sw utl
Internal system error.  User Action:  If problem
persists, contact GE Fanuc Automation - NA.
LAN I/F capacity exceeded; discarded request
Verify that connection limits are not being exceeded.
LAN interface hardware failure; switched off
network
User Action:  Replace Ethernet Interface.
LAN network problem exists; performance
degraded
Excessive backlog of transmission requests due to
excessive traffic on the network.  For a sustained period
the MAC was unable to send frames as quickly as
requested.  User Action:  If problem persists, contact GE
Fanuc Automation - NA.
LAN severe network problem; attempting
recovery
External condition prevented transmission of frame  in
specified timeframe.  Could be busy network or network
problem.  User Action:  Check transceiver to make sure it
is securely attached to the network.  Check for
unterminated trunk cable.
LAN system-software fault; aborted
connection resuming
Internal system error.  User Action:  If problem
persists, contact GE Fanuc Automation - NA.
LAN system-software fault; restarted LAN I/F
Internal system error.  User Action:  If problem
persists, contact GE Fanuc Automation - NA.
LAN system-software fault; resuming
Internal system error.  User Action:  If problem
persists, contact GE Fanuc Automation - NA.
LAN transceiver fault; OFF network until
fixed
Transceiver or transceiver cable failed or became
disconnected.  User Action:  Reattach the cable or replace
the transceiver cable.  Check SQE test switch if present on
transceiver.
Local request to send was rejected; discarded
request
Internal error. Check that the Ethernet Interface is online.
User Action:  If problem persists, contact GE Fanuc
Automation - NA.
Memory backup fault; may lose config/log on
restart
Internal error accessing FLASH device.
User Action:  If problem persists, contact GE Fanuc
Automation - NA.  Replace Ethernet Interface.
Module software corrupted; requesting reload
Catastrophic internal system error.  Contact GE Fanuc
Automation - NA.
Module state doesn’t permit Comm_Req;
discarded
COMMREQ received when Ethernet Interface cannot
process COMMREQ.  User Action:  Make sure Ethernet
Interface is configured and online.
Unsupported feature in configuration
PLC firmware does not support Ethernet communications
software or attempt has been made to configure a feature
not supported by the Ethernet Interface.  User Action:
Check CPU and Ethernet Interface revisions, order
upgrade kit for CPU and/or Ethernet Interface.
Network Adapter does not support Ethernet
Global Data
Ethernet Interface does not support Ethernet Global Data
operation.  User Action:  Check Ethernet Interface
revision; order upgrade kit for Ethernet Interface.
www.cadfamily.com    EMail:cadserv21@hotmail.com
The document is for study only,if tort to your rights,please inform us,we will delete