Cabletron Systems EMM-E6 User Manual

Page of 118
Alarm Configuration
3-2
Using Alarm Configuration
Using Alarm Configuration
To open the Alarms window
from the icon:
1.
Click on the appropriate EMM-E6 icon to display the icon menu.
2.
Drag down to Alarm Configuration and release.
from the Hub View:
1.
In the Hub View, click on 
 to display the Device menu.
2.
Drag down to Alarm Configuration and release to open the Repeater Alarms 
window.
from the command line (stand-alone mode):
1.
From the appropriate directory type:
spmarun r4al <IP Address> <community name>
Figure 3-1. Repeater Alarms Window
NOTES
The spmarun script invoked first in the above command temporarily sets the environment 
variables SPMA needs to operate; be sure to use this command any time you launch an 
application from the command line. The script is automatically invoked when you launch 
the application from the icon menu or from within the Hub View.
If you wish to change any Alarm Configurations, be sure to use a community name with 
at least Read/Write access. If you only wish to view current settings, a community name 
with Read access will be sufficient.
If there is a hostname mapped to your EMM-E6’s IP address, you can use <hostname> 
in place of <IP address> to launch this application. Please note, however, that the 
hostname is not the same as the device name which can be assigned via Local 
Management and/or SPMA; you cannot use the device name in place of the IP address.