Agilent Technologies Cell Phone Accessories E6380-90073 User Manual

Page of 352
Chapter 1
149
GPIB Command Dictionary
CGENerator subsystem
:EVENsec <string>
:EVENsec?
These commands set/query the even-second input’s setting. When 
enabled, signals applied to the EVEN SECOND SYNC IN port 
synchronize the Test Set’s timing circuits.
Syntax
CGEN:EVEN ‘Enable’
 ‘Not’
CGEN:EVEN?
Screen/field equivalent
CGEN:EVEN controls the 
Even Sec In
 field of the CDMA 
GENERATOR screen.
:SPECial <string>
:SPECial?
These commands set/query the rotation of IQ modulated signals. 
Normal creates and analyzes IQ signals with standard rotation. 
Inverted creates and analyzes IQ signals with reverse-rotation. 
(Reverse rotation is opposite to the direction specified in the IS-95 
standards.) 
Syntax
CGEN:SPEC ‘Normal’
 ‘Invert’
CGEN:SPEC?
Screen/field equivalent
CGEN:SPEC controls the 
Gen Special
 field of the CDMA 
GENERATOR screen. This field is also displayed on the CDMA 
ANALYZER screen