Time & date configuration
This page allows you to configure all aspects relating to time and date within the 
AdderView CATxIP 5000 unit.
Timezone specifier
Optionally enter a recognised timezone specifier related to the current position 
of the AdderView CATxIP 5000 unit. When an NTP server is used, the specifier 
will be used to provide the correct real time.
The timezone specifier takes the following form: 
     
std offset dst [offset],start[/time],end[/time]
The 
std
 and 
offset
 specify the standard time zone, such as GMT and 0, or CET 
and -1, or EST and 5, respectively. 
The 
dst
 string and 
[offset]
 specify the name and offset for the corresponding 
Daylight Saving Time zone; if the 
offset
 is omitted, it defaults to one hour ahead 
of standard time. 
The remainder of the specification describes when Daylight Saving Time is in 
effect. The 
start
 field is when Daylight Saving Time goes into effect and the 
end
 field is when the change is made back to standard time. The most common 
format used for the daylight saving time is: 
M
m
.
w
.
d
 
Where: 
m specifies the 
month and must be between 
1 and 12. The day 
d
 
must be between 
0 (Sunday) and 6. The week 
w
 must be between 
1 and 5
week 
1 is the first week in which day 
d
 occurs, and week 
5 specifies the 
last
 
d
 
day in the month. 
The 
time
 fields specify when, in the local time currently in effect, the change to 
the other time occurs. If omitted, the default is 
02:00:00
Typical examples are:
UK:    
 
 
GMT0BST,M3.5.0/1,M10.5.0/2
Central Europe:   
 
CET-1CEST,M3.5.0/2,M10.5.0/3
US Eastern:  
 
 
EST5EDT,M3.2.0/2,M11.1.0/2
US Pacific:  
 
 
PST5PDT,M3.2.0/2,M11.1.0/2
For further details
•  For details of timezone specifier formats, please refer to: 
•  For details of the Network Time Protocol (main RFC number: 1305; the SNTP 
subset used as the basis for the AdderView CATxIP 5000: 4330) 
 
 
Time and Date
Use the arrow buttons to set the correct current time.
Use NTP
When this option is selected, the AdderView CATxIP 5000 will synchronise its 
internal clocks using information from the (Network Time Protocol) server listed 
in the NTP Server IP address field. 
NTP Server IP address
Optionally enter the IP address for a known Network Time Protocol server.  
Set Time from NTP Server
Click to immediately use the time and date information from the listed NTP server.