Adams Infra-Red Heater User Manual

Page of 4
GAS BURNER
• Burner and controls CSA listed for United States and Canada
• Hot Surface ignition and electronic safety – No Pilot
• 60,000, 80,000, 100,000, 125,000, 150,000, 175,000,
200,000 Btu/hr input sizes (natural or propane gas)
• Combustion Air inlet collar
• Sight glass for monitoring burner operation
• Combustion air proving differential switch
• Electrical & gas controls separated from combustion 
air stream
• Burner Housing 18 GA. galvanized steel
• Electrical – 120 volt/60/1 ph
• CSA listed for Vented or Unvented applications
• (1) year limited warranty
TUBE SYSTEM
• Combustion chamber –10' x 4" OD, 16 gauge aluminized
steel with flared burner mounting flange
• Heat exchanger – as required, remaining system comes
in 10' or 5' 16 gauge aluminized steel
• Flared fitting pipe connector with draw bolts at each joint
for solid compression type fitting – no gaskets or draw bands
• 20' to 70' systems – Straight systems or optional “L” or “U”
shaped systems using 90 deg elbows. (see schedule for
tube lengths available) 
• 10 year limited warranty
REFLECTORS
• High polished parabolic reflectors standard 
• 8' or 4' lengths 
• Reflector shield and tube system supported by heavy gauge
wire hangers placed approx. 7' apart
Sun-Heat Standard System Features
FLARED PIPE FORMS
Male-Female Type Connection
Compression Fitting
No Clamps or Draw Bands
OPTIONAL FEATURES
• Outside combustion air inlet hood with flexible 4" diameter duct
• 90 deg elbows for “L” or “U” shaped configurations
• Diffuser “V” reflector for low mounting applications
• Vent cap adapter (4" dia steel to 4" dia class “B” vent pipe
• Line voltage thermostat
• 24 volt relay to convert line voltage thermostat to
24 volt thermostat
• Burner “ON” running light