Dolby Laboratories DP569 User Manual

Page of 90
Model DP569 User’s Manual 
Setting Up 
2-8 
LED 
State 
Description 
Off 
The Ref In input is not selected. 
Green 
The Ref In input is required and locked without errors. 
Ref In 
Red 
The Ref In input is required, but invalid or not present. 
Off 
Remote interface is disabled. 
Green 
Remote interface is enabled and operating without errors. 
Remote 
Red 
Remote interface is enabled but there is a low-level serial communications error. 
Off 
The timecode input is not required. 
Green 
Input is required and a valid input is detected. 
Timecode 
Red 
Input is required, but invalid (e.g., stop time frame number >25 and timecode 
is at 25 fps) or not present. 
 
2.6.3 Channel 
Activity 
LEDs 
There are six-channel activity LEDs.  
If an input channel is muted because its input source is missing or invalid, the 
respective activity LED will be turned off. 
If the system is missing its clock signal then all activity indicators will be turned off 
even if audio inputs are present. 
Table 2-7 Input Channel Activity LED States 
State 
Description 
Off 
Channel is not used. Channel is muted due to invalid input. 
Yellow 
Channel is selected and less than –60 dBFS.
 
 
Green 
Channel is selected and between –0.1 and –60 dBFS. 
Red 
Channel is selected and is greater than –0.1 dBFS (clip). 
2.6.4 Remote 
Connector 
The front-panel RS-232 port is active only when a connector is physically attached to 
the port and the Remote mode or Download mode is enabled. 
The following front-panel functions are active during the Remote mode: 
•  All front-panel status LEDs. This includes the LEDs on the front-panel preset 
buttons, although the buttons themselves are not active.  
•  The Remote mode remains active whether or not controlling devices are 
attached to the remote ports and whether or not commands are being received. 
Note that commands from the front-panel remote port override any commands 
received from the rear-panel port.