Magnetic Alignment
c.  Magnetic Preamplifier Adjustments
7. Remove  the  Cat.  No. 242  card  and  locate  the  reversible  plug-in  Magnetic  Input
Sensitivity header.
100mV
in
1V in
The CP65 accepts a nominal operating input level of either 100 mV or 1V — chosen
by the position of the reversible plug-in header.  The input impedance of the CP65
is  100K  at  both  input  levels.    In  addition,  some  preamplifiers  may  require  a
termination resistor (usually 600 ohms).  You can connect the termination resistors
at the input barrier strip TB3 and TB4 "from mpu–no nr" terminals on the backplane.
Note that changeover between projector 1 and projector 2 must be accomplished
in the magnetic preamplifier.
If noise reduction is to be used for decoding 70 mm Dolby Stereo soundtracks,
the header on the Cat. No. 242 B-chain card must be  set to the 100 mV position.
If the existing non-Dolby magnetic preamplifiers are used, their compatibility with the
CP65 must be ensured.
8. Re-install the Cat. No. 242 card and restore the NORMAL/BYPASS switch to the
NORMAL position.
A-Chain Alignment Procedures