CAUTION: If you have not already turned the
power off at the breaker or fuse, do so now.
Make sure the gasket is in place before connect-
ing any wires. You may find it convenient to use
the wire hanger provided to hold the fixture to the
junction box during the wiring process.
Connect the junction box wires to the fixture wires.
Twist together and secure with wire connectors.
CAUTION: If you are not controlling additional
fixtures from your JourneyMan
®
 fixture, DO NOT
connect the RED wire.
If you are mounting the JourneyMan
®
 fixture to a
small rectangular box, you will need to use the
universal adaptor as shown below. Other boxes
may require the adaptor adjusted differently.
If you are using a standard octagon or round box,
the adaptor is probably not required.
#6-32
screw
Use these holes and the #8-32
X 3/8" (10 mm) screws provided
to secure the fixture.
Horizontal Box
#6-32
screws
Use these holes
and the #8-32 X
3/8" (10 mm)
screws provided
to secure the
fixture.
Vertical Box
#6-32
screw
If the mounting holes in the fixture base still do
not line up with the threaded holes in the univer-
sal adaptor, you can (1) remove the adaptor and
flip it over or (2) remove the other pair of knock
outs in the fixture base.
Standard Wiring
Universal Adaptor
Black to
Black
White to
White
Junction
Box
Green ground
wire to junction
box ground wire
RED, not
used in most
applications
Gasket