APPENDIX B: CLIPPER BOARD E-POINT JUMPERS 
 
E0:  Forced Reset Control  
 
E-Point 
Description 
Default 
E0 
 
Factory use only; the board will not operate with E0 installed. 
 
Not 
Installed 
 
E3:  Re-Initialization On Reset Control  
 
E-Point 
Description 
Default 
E3 
 
 
Remove Jumper for normal operation. 
 
Jump 1-2 for re-initialization on power-up.   
Not 
Installed 
 
E4:  Watchdog Disable Jumper  
 
E-Point 
Description 
Default 
E4 
 
 
Remove Jumper for normal operation. 
 
Install Jumper to disable watchdog timer.  
Not 
Installed 
 
E5:  Reserved for factory use only  
 
Revision 102 or newer 
E Point 
Description 
Default 
E5
 
3
2
1
 
 
For factory use only; the board will not communicate via 
Ethernet or USB if jumper E5 is installed. 
 
Not 
Installed 
 
Revision 101 or older 
E Point 
Description 
Default 
E5
 
 
 
For factory use only; the board will not communicate via 
Ethernet unless Jumper is installed on pins 1 to 2. 
 
Jumpered 
1-2