Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
Appendix B 
 265 
E13:  Firmware Reload Enable (BOOT SW) 
E-Point 
Description 
Default 
E13 
2
1
 
Install E13 to reload firmware through the communications port. 
Remove jumper for normal operations. 
No Jumper 
 
E14:  Watchdog Disable Jumper 
E-Point 
Description 
Default 
E14 
2
1
 
Jump 1 to 2 to disable Watchdog timer (for test purposes only, can 
be hazardous). Remove jumper to enable Watchdog timer. 
No Jumper 
 
E25-28:  Select Encoder Index input or AENA output (channels 1-4) 
E-Point 
Description 
Default 
E25 
2
1
 
No Jumper for TTL Level input for Ch1 Index signal (C) 
Jumper 1-2 to output AENA1 at Ch1 encoder connector 
No Jumper 
E26 
2
1
 
No Jumper for TTL Level input for Ch2 Index signal (C) 
Jumper 1-2 to output AENA2 at Ch2 encoder connector 
No Jumper 
E27 
2
1
 
No Jumper for TTL Level input for Ch3 Index signal (C) 
Jumper 1-2 to output AENA3 at Ch3 encoder connector 
No Jumper 
E28  
2
1
 
No Jumper for TTL Level input for Ch4 Index signal (C) 
Jumper 1-2 to output AENA4 at Ch4 encoder connector 
No Jumper 
 
E35-38:  Select Encoder Index input or AENA output (channels 5-8) 
E-Point 
Description 
Default 
E35 
2
1
 
No Jumper for TTL Level input for Ch5 Index signal (C) 
Jumper 1-2 to output AENA5 at Ch5 encoder connector 
No Jumper 
E36 
2
1
 
No Jumper for TTL Level input for Ch6 Index signal (C) 
Jumper 1-2 to output AENA6 at Ch6 encoder connector 
No Jumper 
E37 
2
1
 
No Jumper for TTL Level input for Ch7 Index signal (C) 
Jumper 1-2 to output AENA7 at Ch7 encoder connector 
No Jumper 
E38 
2
1
 
No Jumper for TTL Level input for Ch8 Index signal (C) 
Jumper 1-2 to output AENA8 at Ch8 encoder connector 
No Jumper 
 
E40:  USB/Ethernet Communication Firmware Load Enable 
E-Point 
Description 
Default 
E40 
2
1
 
Remove Jumper to reload communication firmware 
Installed