X1-X8: Encoder Feedback, SSI 
X1-X8: D-sub DA-15F 
Mating: D-sub DA-15M 
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
 
Pin # 
Symbol 
Function 
Notes 
 
 
Unused 
 
 
Unused 
 
 
Unused 
EncPwr 
Output 
Encoder Power 5 Volts only 
Data- 
Input 
Data- packet 
Clock- 
Output 
Serial Encoder Clock- 
 
 
Unused 
 
 
Unused 
 
 
Unused 
10 
 
 
Unused 
11 
 
 
Unused 
12 
GND 
Common 
Common Ground 
13 
Clock+ 
Output 
Serial Encoder Clock+ 
14 
Data+ 
Input 
Data+ Packet 
15 
 
 
Unused 
 
 
Note 
 
Some SSI devices require 24V power  which has to be brought in 
externally. Pins #4, and #12 are unused in this case, leave floating. 
 
Hardware capture is not available with Serial Data encoders 
 