Turbo PMAC User Manual 
Turbo PMAC System Configuration and Auto Configuration 
27 
PMAC2 Gate Array IC Clock Control
24
Data
1
3
1
2
n
1
2
n
1
2
n
1
2
n
PWM
Up/Down
Counter
6
Address
1
2
n
1
2
n
x6 Phase
Locked Loop
16
External
Phase
External
Servo
n = 0 - 15
n = 0 - 15
n = 0 - 7
n = 0 - 7
n = 0 - 7
n = 0 - 7
PHASE
SERVO
ADCCLK
DACCLK
PFMCLK
SLCK
DT / PW
PWM COUNT
16
8
40 MHz
Phase
Clock Control
Encoder Sample
Clock Control
PFM
Clock Control
DAC
Clock Control
ADC
Clock Control
Servo
Clock Control
Int/Ext Phase
Int/Ext Servo
PWM Max
Count
PWM Dead Time/
PFM Pulse Width
20 MHz
Max Phase
120 MHz
SIGN
DIR
 
I7m00/I6800 MaxPhase Frequency Control 
I7m00 for Servo IC m (or I6800 for MACRO IC 0) for the IC selected as system clock source sets the 
frequency of the internal MaxPhase clock signal, the maximum possible phase clock frequency.  It does 
so according to the formula: 
3
00
m
7
I
*
2
8
.
964
,
117
)
kHz
(
MaxPhase
+
=
 
At the default value of 6527, it sets a 9.04 kHz frequency for MaxPhase. 
I7m00 also sets the PWM output frequency for all channels on Servo IC m; this frequency is equal to 
exactly half of the MaxPhase frequency. 
I7m01/I6801 Phase Clock Frequency Control 
I7m01 for Servo IC m (or I6801 for MACRO IC 1) for the IC selected as system clock source sets the 
frequency of the phase clock signal for the system, controlling its division from the MaxPhase clock 
frequency.  It does so according to the formula: 
1
01
m
7
I
)
kHz
(
MaxPhase
)
kHz
(
Phase
+
=
 
At the default value of 0 (divide by 1) and the default MaxPhase frequency of 9.04 kHz, this sets a phase 
clock frequency of 9.04 kHz (110 µsec period). 
I7m02/I6802 Servo Clock Frequency Control 
I7m02 for Servo IC m (or I6802 for MACRO IC 1) for the IC selected as system clock source sets the 
frequency of the servo clock signal for the system, controlling its division from the phase clock 
frequency.  It does so according to the formula: 
1
02
m
7
I
)
kHz
(
Phase
)
kHz
(
Servo
+
=