Delta Tau GEO BRICK LV User Manual

Page of 440
Turbo PMAC User Manual 
Setting Up Feedback and Master Position Sensors
 
55
 
 
Hardware Setup 
If just used for power-up commutation position feedback, typically the hall sensors are wired into the U, 
V, and W supplemental flags for a PMAC2-style interface channel.  These are single-ended 5V digital 
inputs on all existing hardware implementations.  They are not optically isolated inputs; if isolation is 
desired from the sensor, this must be done externally. 
Note: 
In the case of magnetic hall sensors, the feedback signals often come back to the 
controller in the same cable as the motor power leads.  In this case, the possibility 
of a short to motor power must be considered; safety considerations and industrial 
design codes may make it impermissible to connect the signals directly to the 
Turbo PMAC TTL inputs without isolation. 
If used for servo position and velocity feedback (PMAC2-style Servo ICs only), the three hall sensors are 
connected to the A, B, and C encoder inputs, so that the signal edges can be counted.  As with quadrature 
encoders, these inputs can be single-ended or differential.  They are not optically isolated inputs; if 
isolation is desired from the sensor, this must be done externally.  There may be applications in which the 
signals are connected both to U, V, and W inputs (for power-on commutation position) and to A, B, and C 
inputs (for servo feedback). 
Turbo PMAC Hardware-Control Parameter Setup 
Hall Sensor Demux Control: I7mn5, I68n5, MI915 
If the hall sensors are connected to the channel’s U, V, and W inputs, you must make sure that bit 1 of the 
channel’s Hall Sensor Demux Control variable is set to the default of 0.  If this bit is set to 1, the 
information in the U, V, and W bits of the channel’s status register is de-multiplexed from the C-channel 
of the encoder input based on the states of the A and B inputs, as with Yaskawa incremental encoders.  
This variable is I7mn5 for Servo ICs, I68n5, for MACRO ICs, and node-specific variable MI915 on a 
MACRO Station. 
Encoder Decode Control: I7mn0, I68n0, MI910 
If the hall sensors are wired into the encoder inputs A, B, and C, the decoding of the signal is determined 
by a channel-specific I-variable.  For (PMAC2-style) Servo ICs, this is I7mn0 (for Servo IC m Channel 
n).  For MACRO IC 0 Channel n* on a Turbo PMAC (a handwheel port encoder), this is I68n0.  For 
encoder channels on a MACRO Station, this is node-specific variable MI910.