Axis User Units 
Typically the axis assigned to the motor using the MLDT for feedback will be given engineering units of 
millimeters or inches.  The scaling is done in the axis definition statement.  With the above example, an 
axis definition statement to create axis user units of millimeters would be: 
#1->41.3X 
An axis definition statement to create axis user units of inches would be: 
#1->1060X 
Setting Up LVDTs, RVDTs, & Other Analog 
Turbo PMAC systems can accept analog voltages from devices such as linear variable displacement 
transducers (LVDTs), rotary variable displacement transducers (RVDTs), capacitive gauges, and 
potentiometers, as feedback through optional analog-to-digital converters.  These voltages must be DC; 
that is, a constant position must be represented by a constant DC voltage (not an AC magnitude).  This 
means if the sensor is fundamentally AC with a carrier frequency (e.g. LVDTs, RVDTs), the sensor signal 
must be demodulated to remove the AC carrier signal before it is connected to the Turbo PMAC system.  
Typically, the vendors of these sensors can provide this kind of signal conditioning. 
Hardware Setup 
The analog signal should be wired into the connector for the analog accessory or option according to the 
directions in the associated manual.  If there is provision for differential inputs, and a single-ended input 
is being used, physically wire the complementary input to the return voltage to get a proper reading 
through the differential receiver. 
Turbo PMAC Hardware-Control Parameter Setup 
Most of the 12-bit A/D converters – as on Acc-36P, Acc-36V, Acc-36E, Acc-6E, and Option 12 – use 
multiplexed converters.  The first step in accessing these for servo use is to de-multiplex the data at a 
fixed high rate.  In Turbo PMAC, this de-multiplexing step is controlled by variables I5060 – I5096.  
Each phase interrupt, one pair of ADCs is read and copied into memory registers and the next pair is 
selected for the next conversion.  Up to 16 pairs of ADCs can be in this ring.  The de-multiplexed data is 
left in registers Y:$003400 – Y:$00341F, where it can be read by the conversion table. 
If the 12-bit A/D converters are in the MACRO Station, this de-multiplexing process is controlled by 
Station variables MI987 and MI989.  It is a fixed de-multiplexing of eight pairs of ADCs from one 
device.  MI989 specifies the address of the ADCs, and MI987 is set to 1 to enable the process.  The 
resulting data is placed in Station registers Y:$0200 – Y:$0207, with each pair of 12-bit values in a 24-bit 
register.