Datel DMS-PS-CM User Manual

Page of 8
Technical enquiries email: sales@murata-ps.com, tel: 
+1 508 339 3000
www.murata-ps.com
TECHNICAL NOTES
Ordering Information and Selection Guide
MPS Part No.  
Rated Power 
Efficiency 
 
V1 Output 
V2 Output 
V3 Output
DMS-PS1-CM 
5 Watts 
75% 
5Vdc/1A 
 — 
 —
DMS-PS2-CM 
5 Watts 
73% 
5Vdc/0.65A 
4.85Vdc/0.2A 
 —
DMS-PS3-CM 
5 Watts 
71% 
5Vdc/0.35A 
4.85Vdc/0.2A 
4.85Vdc/0.2A
DMS-PS4-CM 
10 Watts 
80% 
24Vdc/0.45A 
 — 
 —
DMS-PS5-CM 
10 Watts 
75% 
24Vdc/0.35A 
4.85Vdc/0.2A 
 —
DMS-PS6-CM 
10 Watts 
73% 
24Vdc/0.30A 
4.85Vdc/0.2A 
4.85Vdc/0.2A
DMS-PS7-CM 
16 Watts 
82% 
24Vdc/0.70A 
 — 
 —
DMS-PS8-CM 
16 Watts 
76% 
24Vdc/0.60A 
4.85Vdc/0.2A 
 —
DMS-PS9-CM 
16 Watts 
74% 
24Vdc/0.55A 
4.85Vdc/0.2A 
4.85Vdc/0.2A
DMS-PS10-CM 
16 Watts 
82% 
12Vdc/1.35A 
 — 
 —
1.  Shock Hazard: DMS-PS-CM Series power supplies feature touch-proof 
terminals blocks and fully-isolated plastic construction, thereby greatly reduc-
ing the risk of electrical shock. However, these are mains-powered devices 
whose operation is derived from hazardous and potentially lethal voltages. 
  All service and installation must be performed by qualified personnel, with 
the ac supply voltage de-energized. Before making connections to  any of 
the unit’s terminal blocks, use a digital voltmeter to verify that the ac supply is 
de-energized (off).
2.  AC Supply Fuse (F1): All DMS-PS-CM Series power supplies are equipped 
with a built-in 1A/250V time-lag fuse. Replacement fuses must be of the 
same type and rating; please refer to the Functional Specifications section 
of this datasheet for more information. F1 is conservatively rated in order 
to reduce nuisance tripping which might occur during power-up or output 
overload conditions. However, F1 is primarily intended to provide protection in 
the event of catastrophic failure in the DMS-PS-CM’s ac/dc converter.
IMPORTANT! To ensure safe and reliable operation, DMS-PS-CM 
power supplies must be installed and serviced by qualified 
personnel. Contact Murata Power Solutions if there is any doubt 
regarding their installation and/or operation. Please read all of the 
following technical and application notes BEFORE installing or 
making connections to DMS-PS-CM power supplies.
3.  Fuse Replacement: If any dc-output drops to zero volts, and no fault 
conditions exist within the external load circuitry or the ac mains, F1 may 
have failed. F1 is located on the circuit (etch) side of the pc-board. Fuse 
replacement is performed by first de-energizing and then disconnecting 
the ac mains from TB4. Next, disconnect all load wiring from TB1, TB2, 
and TB3. Lastly, remove the four screws that secure the pc-board to the 
plastic case. After making sure that the new fuse is securely attached to its 
mounting clips, re-assemble the unit using all four screws. Reconnect all 
input and output wiring and re-apply ac power.
  If the unit still does not operate properly, and the ac supply at TB4 is 
measured to be within its specified operating range, the power supply 
is defective and must be replaced. Except for F1, DMS-PS-CM supplies 
contain no other user-serviceable components. 
4.  Wire Gauges and Fusing: All wiring connected to the DMS-PS-CM’s 
terminal blocks must meet the requirements specified in the Functional 
Specifications section. All ac supply and load wiring must be rated for the 
voltages and currents they will conduct and must comply with any code 
or application-mandated requirements pertaining to the user’s specific 
installation. Applications subject to vibration should include adequate strain 
reliefs on both input and output wiring. Install the strain reliefs within 2-3 
inches (5-7.5cm) of the terminal blocks.
  It is recommended that all wiring be rated for 600V and 105°C operation 
(UL1015 type, for example). Also, wire insulation must be stripped to within 
±10% of the dimensions shown in Figure 2. All wires must be inserted 
into their respective terminal blocks such that the screw terminal does not 
pinch their insulation. 
No more than two wires should be connected to 
any single terminal on TB1 through TB4. If two wires are attached to a 
single terminal, be sure to use only two 20AWG (0.5mm
2
) wires on TB1, 
TB2, and TB3, and only two 18 or 20AWG (0.75 or 0.5mm
2
) wires on TB4.
Dangerous, potentially lethal voltages are present during normal 
operation. Disconnect ac mains before servicing. 
Reference document: IEC 417, No. 5036.
Caution, refer to accompanying documents for more informa-
tion. Reference document: ISO 3864, No. B.3.1.
Caution, unit may become hot in normal operation, thereby creat-
ing a potential burn hazard. Disconnect ac mains and then allow 
unit to cool before servicing.  
Reference document: IEC 417, No. 5041.
Figure 2. Insulation Strip Length
0.25"
(6.4mm)
Warnings (Marking)
➀ 
Efficiency typical @120V/60Hz
DMS-PS-CM Series
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs
MPM_DMS-PS-CM_B01
 
Page 3 of 8