BENDIX SD-01-700 User Manual

Page of 32
13
Compressor with up to 25% duty cycle
Footnotes:
1.  With increased air demand the air dryer cartridge needs to be 
replaced more often.
2.  Use the drain valves to slowly drain all reservoirs to zero psi.
3.  Allow the oil/water mixture to fully settle before measuring oil 
quantity.
4.  To counter above normal temperatures at the air dryer inlet, (and 
resultant oil-vapor passing upstream in the air system) replace the 
discharge line with one of a larger diameter and/or longer length. 
This helps reduce the air's temperature.  If suf
fi
 cient cooling occurs, 
the oil-vapor condenses and can be removed by the air dryer. 
Discharge line upgrades are not covered under warranty.  Note: 
To help prevent discharge line freeze-ups, shorter discharge line 
lengths or insulation may be required in cold climates.  (See Bendix 
 
 
 
 
 
Recom- 
Recom- Acceptable
 
 
  Typical  Discharge 
mended  mended Reservoir
 
 
 Compressors 
Line 
Air Dryer 
Reservoir 
Oil Contents
3
 
 
No. of 
Spec'd 
        
Cartridge 
Drain 
at Regular 
 
 
Axles 
 
       
Replacement
1
 Schedule
2
 
Drain Interval
High Air Use 
Low Air Use
e.g. Double/triple trailer, 
open highway coach,  (most) 
pick-up & delivery, yard or 
terminal jockey, off-highway, 
construction, loggers, concrete 
mixer, dump truck, 
fi
 re truck.
e.g. Line haul single trailer 
w/o air suspension, air over 
hydraulic brakes.
e.g. Line haul single trailer 
with air suspension, RV
school bus.
5
or
less
5
or
less
8
or
less
12
or
less
Table A:  Maintenance Schedule and Usage Guidelines
Recom-
mended
Every
Month - 
Max of 
every 90 
days
Every
Month
Every 3
Years
Every 2
Years
Every
Year
I.D.
Vehicle Used for:
Column 1
Column 2
Column 3
Column 4
Column 5
Regularly scheduled maintenance is the single most important factor in maintaining the air brake charging 
system.
Length        
6 ft.
1/2 in.
9 ft.
1/2 in.
12 ft.
1/2 in.
3/4 in.
12 ft.
BASIC test
acceptable
range:
5 oil units
per month.
See
appendix
A.
For oil carry-over 
control
4
suggested
upgrades:
5/8 in.      15 ft.
For oil carry-over 
control
4
suggested
upgrades:
5/8 in.      9 ft.
For oil carry-over 
control
4
suggested
upgrades:
5/8 in.      12 ft.
Compressor with less than 15% duty 
cycle
Compressor with up to 25% duty cycle
Compressor with up to 25% duty cycle
Bendix
®
 BA-921
®
 air compressor 
Bendix
®
 T
u-Flo
®
 550 air compressor 
Bendix
®
 T
u-Flo
®
 750 air compressor 
Bendix
®
 BA-922
®
,
or DuraFlo 596
air compressor
BASIC test
acceptable
range:
3 oil units
per month.
See
appendix
A.
For the
BASIC
Test Kit:
Order
Bendix
P/N
5013711
e.g. City transit bus, refuse, 
bulk unloaders, low boys, 
urban region coach, central 
tire in
fl
 ation.
(See footnote 7)
Bulletins TCH-008-021 and TCH-008-022, included in Appendix B, 
for more information.)
5.  For certain vehicles/applications, where turbo-charged inlet air is 
used, a smaller size compressor may be permissible.
6.  Note: Compressor and/or air dryer upgrades are recommended 
in cases where duty cycle is greater than the normal range (for 
the examples above).
7.  For correct compressor upgrades consult Bendix - Please note 
that because a compressor is listed in the same area of the chart 
does not necessarily mean that it would be a suitable candidate 
for upgrade purposes. 
For Bendix
®
 Tu-Flo
®
 550 and 750 compressors, unloader service is 
recommended every 250,000 miles.