Bosch 24" Compact Vented Dryer Axxis WTV76100CN Owner's Manual

Page of 28
11
Ductwork
To ensure optimum performance, 
the ducting system of the dryer 
should be as short as possible with 
a minimum number of elbows. Your 
dryer will work best when the 
venting system has as few air flow 
restrictions as possible. Exhaust 
ducting which is longer than 
recommended may extend drying 
time, cause lint to accumulate and 
affect dryer performance and dryer 
life-time.
Four-inch (approx. 100 mm, in 
Canada 102 mm) diameter ducting 
should be used. Use either rigid 
metal or flexible metal ducting 
material.
DO NOT use plastic or non-metal 
duct with this dryer.
DO NOT assemble the ductwork 
with screws or fasteners that 
extend into the duct. They will serve 
as an accumulation point for lint. 
Joints should be secured with duct 
tape.
All joints should be tight to avoid 
leaks. The male end of each duct 
section must point away from the 
dryer.
Whether connecting to an existing 
venting system or a new venting 
system, make sure that all ducting 
is clean and free of lint. 
The maximum permitted length for 
both rigid and flexible metal duct is 
shown in the table below.
Note:
Left-hand side exhaust installation 
has a 90° turn inside the dryer. To 
determine maximum exhaust 
length, add one 90° turn to the 
chart.
More than two 90° turns are not 
recommended. For best 
performance, separate all turns by 
at least 4 ft. of straight duct, 
including distance between last turn 
and exhaust hood.
Condensation outlet
If water from condensation builds 
up in the exhaust air duct, it is 
recommended that a condensation 
collector (as commercially 
available) is fitted or that a drain 
hole of approximately 3 mm in 
diameter is introduced in the lowest 
section of the exhaust air duct.
Exhaust vent hood
The exhaust duct must end with an 
approved exhaust vent hood with 
swing out damper(s). DO NOT use 
an exhaust vent hood with magnetic 
latches.
To avoid exhaust restriction, the 
outlet must be a minimum of 
12 inches (30 cm) above ground 
level or any other obstructing 
surface.
Required parts
The parts required for the exhaust 
air system (elbows, lines, exhaust 
air outlets) are not included in 
standard delivery of the dryer.
Number of 
90° Turns 
or Elbows
Rigid Duct Flexible Duct
0
66 ft. 
(2011 cm)
8 ft.
(240 mm)
1
56 ft.
(1707 cm)
2
48 ft. 
(1463 cm)
3
39 ft. 
(1189 cm)
4
30  ft.
(914 cm)