Bosch 8-Dec User Manual

Page of 506
Detectors and Accessories | Magnetic Contacts Recessed Mount | 259
EMK 46 S Z Flush-Mount
Magnetic Contact
Features
▶ Conventional flush-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Head-on flush mounting
▶ Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
EMK 46 S Z
Germany
VdS
G 196041, C   EMK 46 S
Installation/Configuration Notes
Installation notes
Installation is head-on in door or window frames.
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
Installation in ferromagnetic materials is not
permissible.
The supply lines need to be measured electrically
before connection.
1
Contact
2
Magnet
3
Installation offset
Distances diagram
1
Extraction
2
Proximity switch part
Note: If the attached magnets are touching each other, there will
be no tamper zone!
Parts Included
Type
Qty.
Component
EMK 46 S Z
1
Built-in magnetic contact
incl. flange and sleeves
Technical Specifications
Type of installation
Flush, head-on
Permissible operating voltage
Max. 40 V_
Contact type
1-pin (normally) open contact
Permissible contact load
6 VA
Max. 100 V_
Max. 500 mA
Protection category
IP 67
VdS environmental class IV
Permissible
ambient temperature
-25 °C to +70 °C
Housing
Material
ABS
Color
White
www.boschsecurity.com 
 Bosch Security Systems B.V.
5