Bosch 8-Dec User Manual

Page of 506
282 | Detectors and Accessories | Magnetic Contacts Surface Mount
MSA-LZ Surface-Mount
Magnetic Contact
Features
▶ Conventional surface-mount magnetic contact
▶ VdS class B
▶ Parallel or head-on surface mounting
▶ Conventional perimeter protection
Conventional magnetic contacts are used for opening
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
MSA-LZ
Germany
VdS
G 191568, B   MS/MSA-LZ
Installation/Configuration Notes
Installation notes
Installation can be parallel or head-on.
The AG 4 surface mounting housing makes it possible
to install on ferromagnetic materials.
1
Contact
2
Magnet
3
Offset in the axial direction
Parts Included
Type
Quant. Component
MSA-LZ
1
Surface-mount magnetic contact incl. 6 m
cable and AG4 surface mounting housing
with accessories
Technical Specifications
Type of installation
Surface mount, parallel or head-on
Contact
Normally open contact
Permissible contact load
≤ 5 Watt
Switching current
10 A to 100 mA
Switching voltage max.
≤ 110 V_
Switch tolerance
≥ 10
7
Magnet
AlNiCo 500
Switch dimensions
43 x 12 x 12 mm
Magnet dimensions
Ø 8 mm x 30 mm
Parallel installation distance
≤ 15 mm
Temperature range
-25 °C to 70 °C
Connection cable
6 m, LiYY 4 x 0.14 mm
Protection category
IP68
Bosch Security Systems B.V. 
 www.boschsecurity.com
5