Bosch 8-Dec User Manual

Page of 506
Wireless Local Security Network (wLSN) | wLSN Peripherie | 433
Technical Specifications
Environmental Considerations
Environment:
Indoor, dry
EN50131-1:
Environmental Class II
Relative Humidity:
Up to 95%, non-condensing
Temperature (operating):
-10°C to +55°C (+14°F to +131°F)
Mechanical Properties
Color:
Off-white
Dimensions (H x W x D):
12.6 cm x 7.5 cm x 4.5 cm
(5.0 in. x 3.0 in. x 1.8 in.)
Inputs
Type:
One supervised sensor loop
Outputs
Relay:
One Form C relay rated for 2 A at 30 VDC (resistive load)
Power Requirements
Battery Power
Battery Life:
Up to 5 years under normal operating condi-
tions.
Battery Requirements:
Four AA Alkaline batteries
Recommended
Replacements:
Duracell® MN1500 or PC1500, Eveready® E91,
Panasonic® AM-3PIX/B
External Power Supply (optional)
Voltage (supply):
6 VDC to 14 VDC
Transmission and Reception Characteristics
Frequency:
European Security Band
868 MHz to 869 MHz
Range (open field):
1000 m (3000 ft)
Trademarks
Duracell® is a registered trademark of the Gillette Company, USA, in the
United States and/or other countries.
Eveready® is a registered trademark of Eveready Battery Company, Inc.
Panasonic® is a registered trademark of a Matsushita Electric Industrial Co.,
Ltd.
Ordering Information
wLSN Relay Module
Allows the control panel to switch outputs wire-
lessly
ISW-BRL1-WX
www.boschsecurity.com 
 Bosch Security Systems B.V.