Bosch 8-Dec User Manual

Page of 506
Accessories for Control Panels and Keypads | Door Access Control Modules | 91
Door Access Control
Module (DACM)
Features
▶ Supports up to 500 users without PC software and up
to 2,000 users with PC software
▶ Operates as an integrated security system component
or as a stand-alone door controller
▶ Works with a variety of reader types and credential
formats
▶ Users can administer the DACM from the reader
keypad, security system keypad, or PC software
You can use the DACM as a stand-alone single door
controller, or integrate the DACM into a building’s security
system. Use an integrated DACM to arm and disarm the
security system. You can use credentials (cards and key
fobs), personal identification numbers (PINs), or both.
System Overview
The DACM supports the following devices separately or
combined: a proximity reader with keypad, a request-to-exit
(REX) input, a door contact.
1.
DACM Controller
2.
Optional electric door strike
3.
Proximity reader with keypad
4.
Control panel
5.
Proximity card and key fob
6.
Optional door contact
7.
Optional REX input
8.
Desktop or laptop PC
9.
Optional data transfer unit (DTU)
10. 12 VDC power supply for stand-alone systems
In a system with a DACM and an integrated control panel, you
can use a credential to arm an area (partition), disarm an area
(partition), or silence an alarm.
Certifications and Approvals
Country
Listings, Certifications, and Approvals
Europe, Middle East, Af-
rica, and others
X
EN50133-1
Alarm Systems – Access Control Systems for use
in Security Applications
www.boschsecurity.com 
 Bosch Security Systems B.V.
2