Bertazzoni 36 Drop-in Low Edge Cooktop 6-Burner Owner's Manual

Page of 23
 
5
Electrical connection
 
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the 
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is 
about 1W for 5 gas burner version or 2W for 6 gas burners version. 
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) 
grounding plug for your protection against shock hazard and should be plugged directly into a 
properly grounded receptable. Do not cut or remove the grounding prong from this plug.   
 
Wiring diagrams
 
 
    Wiring 
diagram 
description 
 
For hotplate model A see Fig. 13.  
 
 
1. Cable terminal 
For hotplate model B see Fig. 14.  
 
 
2. Ignition switch 
3. Spark generator 
4. Ignition spark 
L. Black 
N. White 
T. Green (earth) 
 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 
Conversion to different types of gas 
Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 
To change the nozzles of the burners  use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 
 
TABLE A: Adapting to different types of gas     
Drop-in cooktop with 5 workyop burners model B3H0..Q7X(2 or 5)D   
Burner
 
Position Inj. 
size
 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass size
  
1/100mm 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
[1/100mm] 
Auxiliary
 
Front R 
92 
NG 
4” 
3750 
1098 
900 
264 
Regulated 
  
56 
LP(Propane)
11” 
3750 
1098 
900 
264 
29 
Semi-Rapid
 
Rear L 
117 
NG 
4” 
6000 
1759 
1500 
439 
Regulated 
 Rear 
73 
LP(Propane)
11” 
6300 
1845 
1500 
439 
36 
Rapid
 
Front L 
155 
NG 
4” 
10400 
2046 
2500 
732 
Regulated 
  
98 
LP(Propane)
11” 
11400 
3339 
2500 
732 
47 
 Centre 
Inner 
80 
NG 
4” 
 
 
900 264 
Regulated 
Dual 
 
50 
LP(Propane)
11” 
NG   17000 
4980 
29 
burner 
Centre Outer 
N°2 x 130 
NG 
4” 
LP    18800 
5507 
Regulated 
 
 
N°2 x 83 
LP(Propane)
11” 
 
 
65 
 
Drop-in cooktop with 6 workyop burners model B3K0..U7X(2 or 5)D 
Burner
 
Position Inj. 
size
 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass size
  
1/100mm 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
[1/100mm] 
Auxiliary
 
Front R 
0,92 
NG 
4” 
3750 
1098 
900 
264 
Regulated 
  
0,56 
LP(Propane)
11” 
3750 
1098 
900 
264 
29 
Semi-Rapid
 
Rear L & C 
1,17 
NG 
4” 
6000 
1759 
1500 
429 
Regulated 
 Front 
0,73 
LP(Propane)
11” 
6300 
1845 
1500 
439 
36 
Rapid
 
Front L 
1,55 
NG 
4” 
10400 
2046 
2500 
732 
Regulated 
  
0,98 
LP(Propane)
11” 
11400 
3339 
2500 
732 
47 
 Centre 
Inner 
0,80 
NG 
4” 
 
 
900 264 
Regulated 
Dual 
 
0,50 
LP(Propane)
11” 
NG   17000 
4980 
29 
burner 
Centre Outer 
N°2 x 1,30 
NG 
4” 
LP    18800 
5507 
Regulated 
 
 
N°2 x 0,83 
LP(Propane)
11” 
 
 
65