Behringer Ultragraph FBQ-Pro FBQ3102 Owner's Manual

Page of 14
13
ULTRAGRAPH PRO FBQ6200/FBQ3102/FBQ1502 User Manual
FBQ1502
Audio Inputs
INPUTS  
RF-filtered, servo-balanced XLR and  
¼" TRS connectors
Impedance 
40 kW balanced and unbalanced 
Maximum input level 
+21 dBu balanced and unbalanced
CMRR  
typ. 40 dB, >55 dB @ 1 kHz
Audio Outputs
OUTPUTS 
servo-balanced XLR and  
¼" TRS connectors
SUBWOOFER OUT 
balanced XLR connector
Crossover frequency 
variable, 30 - 200 Hz
System Specifications
Frequency response 
10 Hz to 200 kHz  ±3 dB
S/N ratio 
22 Hz to 22 kHz >94 dB @ +4 dBu
Distortion (THD) 
typ. 0.006% @ +4 dBu, 1 kHz, Gain 1
Crosstalk 
typ. -65 dB @ 1 kHz
Roll-Off Filter section
Type 
12 dB/oct., Butterworth
Input 
variable (-15 dB to +15 dB)
Low Cut 
switchable, Cutoff @ 25 Hz
High Cut 
Graphic Equalizer
Type 
analog 15-band equalizer
Frequency range 
20 Hz to 16 kHz in 15 bands  
(ISO frequencies)
Bandwidth 
2/3 octave
Control range 
 ±6 dB or  ±12 dB (switchable)
Limiter Section
Attack/Release —
Threshold —
LED meter 
Noise Generator
Type —
LED level meter 
Function Switches
FBQ 
activates the FBQ Feedback 
Detection System
Audio In/Out 
switch to bypass the equalizer functions
I/O Meter In/Out 
Range  
shift of the maximum cut/boost range  
for all 31/15 bands
Low Cut 
activates the high pass filter
Limiter —
Pink Noise 
Subwoofer —
Indicators
Input/output level 
4-segment LED display: 
-20/0/+6 dB/CLIP (output only)
Subwoofer —
Power Supply
Mains Voltage
USA / Canada 
120 V~, 60 Hz
Europe / U.K. / Australia 
230 V~, 50 Hz
Japan 
100 V~, 50 - 60 Hz
General export model 
120/230 V~, 50 - 60 Hz
Power consumption 
22 W
Fuse 
100 - 120 V~: T 630 mA H 
200 - 240 V~: T 315 mA H
Mains connection 
standard IEC receptacle
Dimensions / Weight
Dimensions (H x W x D) 
215 x 44.5 x 482.6x mm 
(8.5 x 1.8 x 19 x")
Weight 
2.34 kg (5.1 lbs)
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may 
be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above 
values and/or illustrations.