Bakers Pride LGF User Manual

Page of 60
Gas Pressure Fryer 
 
Operation 
 
 
14 
Item Description 
Function 
A, B, C, D preset 
buttons 
These buttons are used to save and recall preset cycle and alarm times, 
saving operator time and minimizing error when changing interval cycle 
times and alarm times. To save the current interval and alarm times into 
one of the preset locations, press and hold the A, B, C, or D preset button 
for 2 seconds and the controller will double chirp to indicate the times have 
been saved. To recall any preset time, press and quickly release the 
appropriate button and the time values are loaded and displayed. These 
buttons are also used to reconfigure the STIR OIL function. 
 
Beeper 
A beeper sounds when the timer counts down to 0. Pressing the 
START/STOP button stops the beeper and resets the timer causing the 
display to return to the original starting time. At this point, time can be 
changed using the TIME SELECT buttons or the preset buttons. The 
beeper will also sound for 10 seconds if the alarm time has elapsed during 
a timing cycle. When the STIR OIL function begins the beeper will sound 
until the ALARM or START/STOP button is pressed. 
 
Display 
Used to display the time. It also displays the words “STIR” then “OIL” in .5 
second intervals until the ALARM or START/STOP button is pressed. 
High Limit Reset Switch 
If shortening inside the pot reaches an unsafe temperature, power is 
automatically removed from the control panel and the gas system shuts 
off. Pressing this switch returns power to the control panel and resets the 
gas system. 
10 
Gas Control Valve Switch 
ON – Allows gas to flow when the FILTER/OFF/FRY switch is set to the 
FRY position and the thermostat calls for heat. 
 
OFF – Prevents gas flow regardless of FILTER/OFF/FRY switch and 
thermostat settings. 
11 
Drain Lever 
DRAIN OPEN – When placed in this position, the drain valve opens and 
shortening drains into the vat. Also power is removed from the control 
panel and gas system. 
 
DRAIN CLOSED – When placed in this position, the drain valve is closed 
to prevent shortening from draining into the pot. Also power is restored to 
the control panel and gas system. 
12 
Fill Lever 
FILL THRU POT – When placed in this position, shortening will be pumped 
from the vat to the pot if the rocker switch is in the FILTER position. 
 
FILL THRU HOSE – When placed in this position, shortening will be 
pumped from the vat to the pot via a fill hose if the rocker switch is in the 
FILTER position. 
13 
Pump Motor Reset Switch 
If the motor overheats while filtering, it will automatically shut off. Wait 15 
minutes to allow motor to cool before pressing this switch.  
14 
Rinse Hose Connector 
Used to connect the Rinse hose for cleaning and refilling the pot.