TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered.  If  the  problem  remains  after  exhausting  the  troubleshooting  steps,  contact  the  Bunn-O-Matic 
Technical Service Department.
•  Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
•  All electronic components have 120-240 volt ac and low voltage dc potential on their terminals. Shorting of 
terminals or the application of external voltages may result in board failure.
•  Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If 
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a 
terminal or crimp.
•  Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are 
energized for more than ten minutes without a supply of water.
•  The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will 
help to avoid twists and kinks in the tubing.
•  Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
WARNING  –  •  Exercise extreme caution when servicing electrical equipment.
 
  •  Unplug the dispenser when servicing, except when electrical tests are specified.
 
  •  Follow recommended service procedures.
 
  •  Replace all protective shields or safety notices.
Cold Water Circulation
Dispense stations not working.
Note: Cooling failure or excessive 
cabinet  temperatures  for  more 
than 4 hours will result in dispense 
lockout or no dispense.
Note: Reset fault/timer by unplug-
ging unit.
1. Cabinet cooling fan.
2. Bath recirculation pump.
3. Restricted water flow to cabinet 
water coil and bath.
Replace fan (24vdc).
Note: Fan receives power when the 
dispenser is powered.
A) If not running, check refrigera-
tion switch and wiring for proper 
continuity.
B) Check for 120V or 230V AC at 
pump. Replace pump. 
Check for kinked hose.
PROBLEM
PROBABLE CAUSE
REMEDY