4. VACUUM 
MOTOR 
Vacuum Motor Carbon Brushes Replacement (Windsor) 
WARNING: The green 
ground wire must be 
attached for safe operation. 
See wiring diagram. 
(Refer to vacuum group in the parts section of 
manual). 
End Cap 
4-3
 
 
ONLY QUALIFIED MAINTENANCE PERSONNEL 
ARE TO PERFORM THE FOLLOWING REPAIRS. 
 
VACUUM MOTOR REPLACEMENT 
1.  
Turn off all switches and unplug machine. 
2.  Remove recovery tank. 
3.  Remove the 5 screws holding the vacuum motor 
cover to the solution tank. 
4.  Locate the vacuum motor wires and disconnect 
at the connector. 
5.  Remove the vacuum motor. 
6.  Reverse process to install. 
 
Carbon  
Brushes  
If armature commutator is grooved, extremely pitted or not 
concentric, the motor will need to be replaced or sent to a 
qualified service center. 
Important: 
These brushes wear quicker as the length shortens due to 
increased heat. Spring inside brush housing will damage 
motor if brushes are allowed to wear away completely. 
Periodically check the length of the carbon brushes. Replace 
both carbon brushes when either is less than 3/8" (9.5mm) 
long. 