The following tables detail the technical specifications for the 
iPump 562
.
RF Characteristics
Table 1.3: iPump 562 RF Characteristics
Contact Closure GPIO DB-9 Female 
Connector Pin 
Input/Output 
Description
1
Alarm Common
2
Alarm Normally Open
3
Contact Closure Common
4
No Connection
5
Input
Contact Closure GPIO Input 
 
(Factory use only)
6
Alarm Normally Closed
7
Contact Closure Normally Closed
8
Contact Closure Normally Open
9
NA 
Ground
Power DC IN 12 V 5 A
Connector
Input/Output 
Description
Standard IEC
Input 
115 or 230 V AC
External Input/Output Interfaces
RF Characteristics
RF Input 
Connector Type F
Input Frequency Range 
950 - 2150 MHz
Input Level Range 
-25 to -65dBm
Maximum Aggregate Input Power 
-8 dBm at max input signal
Input Impedance 
75 ohms
Input VSWR 
< 2.5:1
Input Noise Figure 
8 dB MAX at minimum input level
L.O. Leakage at Input 
< -55 dBm
Demodulator 
DVB-S QPSK 
DVB-S2 QPSK 
DVB-S2, 8PSK
FEC Rate 1/2, 2/3, 3/4, 5/6, or 7/8 (1.0 to 45 MBaud) ½, 2/3, 
¾, 4/5, 5/6, 7/8, 9/10 (2 to 30 MBaud) 2/3, ¾, 5/6, 8/9, 9/10 
(3 to 30 MBaud) Convert Symbol Rate Fs to Transport Rate 
Ft by: (2R*Fs)*(188/204)=Ft, where 'R' is inner FEC code 
ratio, either R=1/2, 2/3, 3/4, 5/6, or 7/8.
Max Symbol-rate 
S2 = 30 Msps; S1 = 45 Mbps