7/50D Plus or 7/50D Controller 
Chapter 6:  Configurable Settings 
76 
Name Description 
Options 
Default 
On time 
Number of seconds that the each air pulse lasts 
during filter cleaning. 
If blow-back is not working as desired, the  
service department may ask you to change this 
setting. 
0.1–99.0 sec.  1.0 sec. 
Off time 
Number of seconds between air pulses during 
filter cleaning. 
If blow-back is not working as desired, the 
service department may ask you to change this 
setting. 
0.5–99.0 sec.  1.0 sec. 
Slide Gate Options  (Only available on 7/50D Plus systems) 
Slide gate 
When this option is enabled, the controller 
opens the slide gate between the station and 
the receiver during the dump delay and during 
blow-back. 
Enable this option if and only if the station has a 
slide gate instead of a flapper and demand 
switch. 
disabled, 
enabled 
disabled 
Purge Options 
Purge 
When enabled, this option allows the system to 
empty the material line completely after every 
convey to this station. The station’s pump 
continues to draw without picking up material for 
an extra period of time after conveying is 
finished. 
Enable this option if and only if you are using a 
purge valve for this station. This option cannot 
be used with a volume-fill station. 
disabled, 
enabled 
disabled 
Purge duration 
Number of seconds allowed for purging. The 
station’s vacuum valve remains open for the 
convey time plus this time. 
Adjust this setting to the amount of time 
required for material to travel from the pickup 
point (purge valve) to the station. 
Ø–999 sec. 
20 sec. 
Purge valve 
Number (address) for the purge valve used with 
this station. 
Set this to match the number (address) for the 
purge valve that services this station. If another 
station has the purge valve that services this 
station, enter the number of that station (range: 
1–50). If a central purge valve services this 
station, enter the number (address) of that valve 
(range: 51–154). 
1–154 
0 (= not 
assigned) 
Material Proofing Options 
Material proofing 
When this option is enabled, the controller 
issues an alarm for the station if the number for 
“Material set to” does not match the number for 
the actual material. These numbers refer to 
material lines. 
Enable this option if and only if your facility has 
installed the option of material proofing and you 
want to check the material line connected to this 
station. 
disabled, 
enabled 
disabled