.  8 fully isolated semiconductor switched outputs
.  Controls solenoids and relays
.  For load supplies of up to 250 V ac
.  Discrete or pulsed outputs
.  1A per channel switched
Module Specifications  
Outputs
Number of channels ...........................................................................8
Output voltage range.....................................................20–265 V ac
Frequency ............................................................................50 / 60 Hz
ON voltage drop........................................................................< 1.2 V
OFF leakage current ...............................................................< 4 mA
Switched current per channel †
     Continuous.................................................................................1 A*
     For < 100ms .................................................................................5 A
     For < 20ms .................................................................................20 A
Minimum load current, per channel
     @ 115 V ac...............................................................................11 mA
     @ 230 V ac.................................................................................5 mA
Configurable Parameters
Output initialization state...................................predefined value
Fail-safe.................................................predefined value/last value
Output .....................discrete, momentary or continuous pulse‡
Pulse width.....................................................................2 ms to 130 s
Response Time
Response time (max.) ..2 ms + 11⁄42 cycle of mains frequency
(From Railbus command to output change)
Power Supplies
Railbus (12V) current......................................................75 mA (typ.)
.........................................................................................125 mA (max.)
Bussed Field Power .......................................................not required
NT
-8118-DO-AC
Image Description
8-channel Discrete Output
20–265 V ac, isolated, unpowered
Mechanical
Module Key Code .............................................................................F4
Module width ...........................................................................42 mm
Weight............................................................................................220 g
Field Terminals 
Field Wiring
Recommended 
Field Terminal
Compatible 
Field Terminal
General Purpose
NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard 
Class 1, Div 2 
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing
† Stated figures are for operation with unfused field terminal. 
When operating with 2 A fused field terminal part no. NT-
8604-FT-FU, maximum switched current is 5 A inrush for <10 
ms pulse width at 0.1% duty cycle and <10
8
 operations.
* Limited to 3 A per module.
‡Consult NovaTech for availability