The  diver  must  report  to  the  surface  immediately 
after the entry. It is a good policy to descend 10 or 
20 FSW (3-6 MSW), pause and check the regulator 
adjustment knob to ensure adjustment for the least 
breathing resistance.  
The purpose of this adjustment knob is to allow the 
diver the ability to compensate for variations in um-
bilical supply pressure. This adjustment device oper-
ates by simply increasing or decreasing the amount 
of spring bias tension on the demand regulator inlet 
valve. 
This adjustment device is not intended as a minimum-
maximum device. Minimum and maximum applies to 
supply pressure only. The adjustment knob should be 
adjusted by the diver to be at the easiest breathing 
setting at all times. 
Diving a KMDSI helmet or band mask with a bias 
setting greater than that just necessary to keep the 
demand valve from free flowing increases the work of 
breathing and reduces the  diver’s ability to perform 
heavy work.
Then  the  diver  checks  in  with  the  surface  before 
descending to the job. If a closed bell is being used, 
the diver enters the water from the bell and pauses 
for a short time outside the trunk until he is sure all 
systems are operating properly.
During  the  decent  the  communications  must  be 
checked again and the diver supply pressure should 
be  adjusted  as  necessary  to  maintain  the  required 
over-bottom  pressure.  It  may  be  necessary  for  the 
diver to readjust the demand regulator by means of the 
adjustment knob  once at the work site to compensate 
for the variation in umbilical supply pressure.
3.11  Emergency Procedures
3.11.1 Flooding
In the event of partial or complete flooding, the diver 
may  clear  the  helmet  quickly  by  tilting  the  helmet 
forward and slightly down and activating the defogger 
control knob.  Pressing in on the manual purge but-
ton  in the center of the regulator cover will dewater 
the regulator.  
After clearing, cautiously check for additional flood-
ing. If the helmet continues to take on water, return 
to the diving station, swimming with the water dump 
valve positioned at the lowest part of the hat:  that is 
with the diver’s face forward and slightly tilted down.  
Keep the free flow knob on. This increases the air/gas 
pressure slightly inside the hat and keeps the water 
out. Any incoming water is automatically purged.
3.11.2 Inhalation Resistance
If  breathing  becomes  difficult,  adjust  the  demand 
regulator  adjustment  knob,  for  easier  breathing  by 
rotating  the  adjustment  knob  counter  clockwise.  If 
the breathing does not get noticeably better, press the 
purge button in the regulator cover. If a surge of gas 
does not flow with this action, open the emergency 
valve. 
If the flow is noticeably better, immediately notify 
topside that you are on emergency gas. Insure your 
umbilical is clear and return to the stage or decent line. 
The diver should stay in communication with topside 
personnel and make preparations to abort the dive. 
The console operator should check to ensure the sup-
ply pressure to the diver is at the proper pressure.
3.11.3 Gas Flow Stops
A stop of flow in the demand regulator usually in-
dicates the main gas supply has stopped. The diver 
should  first  open  the  emergency  valve    by  turning 
the knob. If there is still no flow from the demand 
regulator, the defogger valve knob  should be opened.  
Keep in mind that if the defogger valve is left open, 
the bailout bottle will drain very quickly, particularly 
if the diver is deep. 
Immediately  notify  topside,  check  to  insure  your 
umbilical is clear and return to the diving station us-
ing the emergency breathing supply. Avoid making a 
rapid ascent if at all possible.
Once at the surface, or inside the bell, the diver may 
remove the helmet if needed.  Never ditch the hel-
met underwater unless conditions absolutely require 
that.