CyberPower Battery Charger CPBC6200AC Leaflet

Page of 1
PACKAGE CONTENTS
• USB Battery Pack (CPBC5200AC Series)
• User Guide
SPECIFICATIONS
Battery Capacity: 5200mA
Rated Input: AC 100~240V, 50/60Hz 0.4A
Rated Output: DC 5V 2.1A (Max.)
PC Charging time: ~6 Hours
Dimension: 4.26x2.2x0.96 inch
Weight: 5.93 oz
Environment:
Storage: 14 to 122°F (-10 to 50°C)
Operation: 32 to 104˚F (0 to 40˚C)
SUGGESTED - PRIOR TO FIRST USE:
It is recommended that you charge
your CPBC5200AC Series battery pack for 
10 hours to insure a full charge.
CHARGING THE BATTERY PACK
Charge the USB Battery Pack by putting the plug into an AC 
socket. When charging the battery pack, the LED indicator will 
light up automatically. Press the button to turn it off and press 
it again to switch the LED indicator on. Recharge the 
CPBC5200AC Series every 3 months when not in use to 
maintain peak battery performance. The battery capacity may 
decline after 300 charging cycles.
SAFETY PRECAUTION
Before using the USB Battery Pack, please read the following 
warnings carefully. Use the product according to the 
procedures described in this manual. Failure to follow these 
safety precautions may result in fire, explosion, electrical shock 
or other dangers
1. Store between 14 to 122°F (-10 to 50°C).Operate between 
32 to 104°F(0 to 40°C).
2. Do not immerse this product in water or other liquids, as 
such use may result in fire or electrical shock. If water or 
other liquids enter the battery interior, unplug the product 
immediately from any attached power source or device. 
3. Do not use this product with wet hands. Moisture in or on 
this product may result in electrical shock.
4. Store this product in a cool and dry environment when not in use.
5. Do not puncture this product. Puncturing the battery may 
cause the release of harmful substances.
6. It is normal for the USB Battery Pack to become warm 
during charging.
7. Ensure that all users read these warnings and instructions 
before using.
8. Please recycle USB Battery Pack in accordance with local 
environmental laws and regulations
9. Do not dismantle, open or shred secondary cells or batteries.
10. Do not expose cells or batteries to heat or fire. Avoid storage 
in direct sunlight.
11. Do not short-circuit a cell or a battery. Do not store cells or 
batteries haphazardly in a box or drawer where they may 
short-circuit each other or be short-circuited by other metal 
objects.
12. Do not remove a cell or battery from its original packaging 
until required for use.
13. Do not subject cells or batteries to mechanical shock.
14. In the event of a cell leaking, do not allow the liquid to come 
in contact with the skin or eyes. If contact has been made, 
wash the affected area with copious amounts of water and 
seek medical advice.
15. Do not use any charger other than that specifically provided 
for use with the equipment.
16. Observe the plus (+) and minus (–) marks on the cell, battery 
and equipment and ensure correct use.
17. Do not use any cell or battery which is not designed for use 
with the equipment.
18. Do not mix cells of different manufacture, capacity, size or 
type within a device.
19. Keep cells and batteries out of the reach of children.
20. Seek medical advice immediately if a cell or a battery has 
been swallowed.
21. Always purchase the correct cell or battery for the equipment.
22. Keep cells and batteries clean and dry.
23. Wipe the cell or battery terminals with a clean dry cloth if 
they become dirty.
24. Secondary cells and batteries need to be charged before 
use. Always use the correct charger and refer to the 
manufacturer’s instructions or equipment manual for proper 
charging instructions.
25. Do not leave a battery on prolonged charge when not in use.
26. After extended periods of storage, it may be necessary to 
charge and discharge the cells or batteries several times to 
obtain maximum performance.
27. Secondary cells and batteries give their best performance 
when they are operated at normal room temperature (20 
°C ± 5 °C).
28. Retain the original product literature for future reference.
29. Use only the cell or battery in the application for which it 
was intended.
30. When possible, remove the battery from the equipment 
when not in use.
31. Dispose of properly.
LEGAL NOTICES
FCC Part 15
This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to Part 15 of the FCC 
rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This 
equipment generates uses and can radiate radio frequency 
energy and if not installed and used in accordance with the 
instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference 
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
– Increase the separation between the equipment 
and receiver.
– Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV 
technician for help.
If the LED indicator extinguishes automatically during the 
charging process, press the button to revert.
FCC WARNING
Changes or modifications not expressly approved by the 
party responsible for compliance with the FCC Rules could 
void the user’s authority to operate this equipment.
LIMITED PRODUCT WARRANTY
CyberPower offers limited product warranty for the hardware 
of the USB Battery Pack and the product is free from material 
and manufacturing defects for one year.  A reasonable 
purchase proof with date must be provided when submission. 
CyberPower's sole responsibility is to repair or replace the 
product if a material or manufacturing defect results in 
product failure during its normal use. The warranty is void if 
the product is damaged due to abuse, alteration, misuse, 
negligence, incorrect voltage supply, air/water pollution, 
accidents and natural disasters.
INTRODUCTION
The USB Battery Pack (CPBC5200AC Series) is a high 
capacity rechargeable lithium battery designed for 
powering up to two mobile devices such as phones, MP3 
players, tablets, and handheld gaming devices while away 
from other power sources
FEATURES
- Compact and portable design
- Dual output
- Built in AC plug
- Battery life indicator
PRODUCT VIEW:
© 2013 CyberPower Systems, Inc. 
All rights reserved. Reproduction in whole or in part without permission is prohibited.
USB BATTERY PACK
USER GUIDE
Model: CPBC5200AC Series
TROUBLE SHOOTING
K09-0000172-00
POWER 
YOUR DEVICES
CHARGING THE 
POWER PACK
PAD
ITEM
NO.
DESCRIPTION
1
2
3
4
5
Power on/ LED Indicator Switch
Power Off 
LED Battery Life lndicator 
USB Output Port 1*
USB Output Port 2
AC Input Plug
Press the button
Press and hold for 3 seconds
As the “LED INDICATOR”
table showing
5V/ 2.1A (Max.) USB output
AC 100~240V, 50/60Hz, 0.4A
CONDITION
NO.
LED INDICATION
1
2
3
Battery Life Indicator
Overload
Low Battery
Four LEDs represent 25%,
50%, 75% and 100% battery
life from left to right side. 
All four LEDs flash simultaneously.
The first LED light flashes rapidly.
LED INDICATOR
Problem
Possible Cause
Solution
USB Battery
pack does
not recharge
1.Incorrect connection 
between charger and 
USB Battery Pack.
2.No power from the 
source.
Re-attach the USB connector 
to the socket.
Check that power is provided 
Problem
Possible Cause
Solution
USB Battery
Pack does
not power
the device
1.The device is drawing 
too much power.
2.The battery is out     
of power
Check the power specification 
of the device before charging 
with the CPBC5200AC Series.
Charge the battery pack.
*Charge tablets and Apple devices through USB Output Port 1 to achieve fast charging.
1
2
3
4
5
Note: 
1. The LED indicator will automatically switch off 5 seconds 
after pressing the button.
2. When the battery pack is connected to the power, the LED 
indicator will light indicating the charging status. Press the 
button to switch off the indicator and press the button again 
to switch it back on.
CyberPower Systems (USA), Inc. 
4241 12th Avenue East, Suite 400, Shakopee, MN 55379, U.S.A. 
TEL: (952) 403-9500    Toll-Free: (877) 297-6937
FAX: (952) 403-0009    E-mail: tech@cpsww.com
CPSww.com