3.7  User Buttons SW1, SW2, SW3, SW4, SW5, SW6 (JP: 3, 4, 5, 6, 7) 
Five user push buttons (SW1-SW5) can be connected to the microcontroller. 
JP3, 4, 5, 6, 7 
Each push button can be connected separately. 
Jumper 
Setting 
Description 
Closed 
Pin 139 (INT0/NMI) of the MCU is connected to “SW1” 
JP3 
(SW1) 
Open 
No connection to the microcontroller 
Closed 
Pin 19 (FRCK0) of the MCU is connected to “SW2” 
JP4 
(SW2) 
Open 
No connection to the microcontroller 
Closed 
Pin 22 (TIN1) of the MCU is connected to “SW3” 
JP5 
(SW3) 
Open 
No connection to the microcontroller 
Closed 
Pin 20 (IN0/TTG4/0) of the MCU is connected to “SW4” 
JP6 
(SW4) 
Open 
No connection to the microcontroller 
Closed 
Pin 21 (IN1/TTG5/1) of the MCU is connected to “SW5” 
JP7 
(SW5) 
Open 
No connection to the microcontroller 
Table 3-6: User Push Buttons 
 
Default: JP3, 4, 5, 6, 7 closed 
By default, all push-buttons are connected to the microcontroller. 
 
3.8 I
2
C pull-up resistor (JP: 9, 10) 
Two 10k pull-up resistors can be connected to the I
2
C signal line. 
JP9, 10  10k pull-up resistors can be connected to SDA0 and SCL0 
Jumper 
Setting 
Description 
Closed 
A 10k pull-up resistor is connected to SDA0 
JP9 
(SDA0) 
Open 
No pull-up resistor is connected to SDA0 
Closed 
A 10k pull-up resistor is connected to SCL0 
JP10 
(SCL0) 
Open 
No pull-up resistor is connected to SCL0