Aube Technologies TI040 Leaflet

Page of 2
TI040
      400-040-001-A                    15/1/07                    1/2
TI040
Installation and User Guide
Industrial Indoor / Outdoor Timer
n
Cut power at the circuit breaker to avoid electric shock.
o
Perform the connections as shown on the wiring diagram.
NOTE: For a 3-way installation, connect a standard single-pole
switch to the 3-way terminals of the timer as shown on the wiring
diagram.
p
Select the proper operating voltage.
q
Apply power at the circuit breaker.
At power-on, 0:00 will flash. Otherwise, press reset using a paper
clip. If the display is blank, verify the power supply.
NOTE: The switch displays the time in 24-hour format by default or
following a reset. 
n
To change to 12-hour format (or vice versa), proceed as follows:
a) Press the MODE button to ensure the MAN or AUTO indica-
tor is displayed.
b) Press the MIN and HOUR buttons simultaneously and briefly 
(0:00 display = 24-hour, 12:00 display = 12-hour).
o
Set the time using the HOUR and MIN buttons. If you have 
selected the 12-hour format, ensure that PM appears on the 
screen when an afternoon time is displayed.
p
Set the day by using the DAY button.
q
Press the MODE button to return to normal operation.
The programmable switch has 2 operating modes: manual (MAN)
and automatic (AUTO). To switch mode, press the MODE button for 3
seconds.
Manual Mode
In Manual mode, the timer operates like a regular switch. Briefly
press the MODE button to activate or deactivate the load. (If you
have connected a remote switch to the timer for a 3-way installation,
the switch can also be used to activate or deactivate the load.) The
mode indicator (MAN) and the state (ON or OFF) are displayed.
Automatic Mode
In Automatic mode, the timer follows the programmed schedule (see
section 6). The mode indicator (AUTO), the state (ON or OFF) and
the current program number are displayed.
To temporarily override the programmed schedule, press the MODE
button or use the 3-way installation switch (if connected). The new
n
Applications
1.
Load type Maximum load
Examples
Resistive
load
30 A
incandescent lights
halogen lights
block heater
Inductive
load
10 A
fluorescent lights
compact fluorescent lights (CFL)
sodium lamps
electronic ballasts
Motor
1.5 hp @ 120 VAC
2.0 hp @ 240 VAC
pool filter pumps
fans
o
Installation
2.
Power supply 
(120/208/
240 VAC)
Single-pole switch 
(for 3-way installation)
Line voltage 
selector 
switch
Motor
Lighting
p
Power-On
3.
q
Setting the Clock
4.
r
Selecting the Operating Mode
5.
 
• Briefly press the 
button to turn the 
load On or Off.
• Press the button for 
3 seconds to switch 
between Automatic 
mode and Manual 
mode.
Mode display
On/Off display
Program number