REPORT COMMOND is “r p.”  The report will show if any sync data cards are
available.  The line will read as follows:
 
Sync Data Card #(1 or 2): INSTALLED
 
 
The SYNC DATA report command is “r sd.”  The report will report the sync data
card status in the following form:
 
FUNCTION  CURRENT SETTING
 
RS422  OUTPUT  ENABLED/DISABLED
 
LVDS OUTPUT
 ENABLED/DISABLED
 
SYNC  DATA  RATE  data rate
 
PID
PID
 
STATUS
 
3.2   From Front-panel
Ÿ 
Sync Data Card setup with local control disabled:
The sync data card setup cannot be accessed via the front panel with local control
disabled.  The Network must authorize local control.
Ÿ 
Sync Data Card setup with local control enabled:
The sync data card can be set via the front panel, if local control is enabled, by using the
menu path HARDWARE SETUP / CONTROL SYNC DATA.  Select the parameter you
need to adjust by using the right/left arrows and the <SELECT> key.  Use the up/down
arrows to select the desired setting.  Press the <ENTER> key to initialize the settings.
Ÿ 
Sync Data Card status:  To confirm that the Sync Data card option is available via the
front panel follow the menu path STATUS REPORTS / PARAMETER STATUS.  Use the
right/left arrow keys to scroll to SYNC DATA.
To view how the sync data card is configured via the front panel follow the menu path
STATUS REPORTS / SYNC DATA STATUS.  Use the right/left arrow keys to scroll
through the audio ports configuration.