Vermont Casting ACSB User Manual

Page of 10
5
Addison Electric Stove
10004324
Hearth
Clearance to Combustibles
Electrical Specifications
WARNING: This stove comes with a
manual circuit breaker reset near the
power cord supply. In case the stove is
not operating, check the circuit breaker
and reset the button at the breaker. If the
stove is still not operating immediately
call a qualified service technician to
inspect the stove.
Voltage ..................................... 120VAC/60Hz
Total Amps ............................... 12.20 Amps
Total Watts ............................... 1460 Watts
Heater Ratings ......................... 1300 Watts
Electrical Connection
A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the stove will
be on a dedicated circuit as other appliances on the
same circuit may cause the circuit breaker to trip or the
fuse to blow when the heater is in operation.
The unit comes standard with a 6’ (1828 mm) long
three wire cord, exiting from the rear of the stove. Plan
the installation to avoid the use of an extension cord. If
an extension cord must be used, it must be a
minumum 14AWG, three wire with grounding type plug
connector and rated not less than 1875 Watts. The
extension cord shall not be more than 20 feet in
length.
WARNING: Electrical outlet wiring must
comply with local building codes and
other applicable regulations to reduce
the risk of fire, electrical shock and
injury to persons.
WARNING: Do not use this stove if any
part of it has been under water. Immedi-
ately call a qualified service technician
to inspect the stove and replace any part
of the electrical system.
A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which does not obstruct heater openings.
Installation of Logs
1. Turn off power to the unit.
2. Follow the directions for removing the firebox. Refer
to Page 6, Steps 1 through 7.
Back ............................................................... 0” (0mm)
Sides .............................................................. 0” (0mm)
Floor ............................................................... 0” (0mm)
Top ........................................................... 12” (305mm)
LG240
Fig. 2  Addison logset.