Scotsman Ice DB-101 User Manual

Page of 34
SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL 
 
Scotsman
 
 
Oct-06
 
KERR SCOTSMAN Wood Furnace         Model DB-101-ADD 
 
Tested and Listed by: 
Energy Testing Laboratory of Maine 
Certified by the Canadian Standards Association  (CSA) Sept. 1981 
 
COSP No.  WCP 001 – Free-Standing 
COSP No.  WCP 005 – Add-On 
 
Manufactured by:  Parrsboro Metal Fabricators Ltd. 
P.O. Box 637, Crossroads 
12118 Highway 209 
Parrsboro Nova Scotia, Canada 
B0M 1S0 
 
SPECIFICATIONS 
 
Length 
 
 
 
39” 
Width  
 
 
 
29” 
Height  
 
 
 
44 1/2”  
Shipping Weight 
 
 
392 lb. 
Fire Box 1/8”plate  Length 
36” 
 
 
 
Diameter 
23” 
Secondary Heat Exchanger 
14 gauge steel 
Fire Box Door 
Cast Iron 
13” x 13” 
Warm Air Plenum   
 
32 1/4” x 25 1/2” 
Return Air Plenum   
 
N/A 
Air Filter Size  
 
 
20” x 20” 
Blower Size   
 
 
G9 – 10 
Blower Motor  
 
 
1/4 hp 
C.F.M. 
 
 
 
1000 (Required) 
Smoke Pipe   
 
 
7” Inside Diameter 
Floor to smoke pipe center  
38 3/4” 
Output (max)  
 
 
140,000 Btu/h 
Fuel   
 
 
 
Wood 30” logs 
Electrical Rating 
 
 
Volts 120, Cycles 60, Amps 15 
 
NOTE – Keep this manual in a safe place for future reference.  Follow manual carefully 
for the correct way to install and operate this unit.   
 
CAUTION  – Do not fire this unit until operating instructions  have been read and fully 
understood. 
 
INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM  
AND CHIMNEY THAT ARE IN GOOD CONDITION. 
 