Perle Systems Iolan Sds4 Hl Device Server 4030370 User Manual

Page of 460
 278
Channels
Field Descriptions
Configure the following parameters:
Description
Provide a description of the channel, making it easier to identify. 
Data Options: Maximum 20 characters, including spaces
Output
Specify how the channel output will be handled.
Data Options:
z
Manual—You must manually manipulate the channel output.
z
Pulse—Activates and deactivates the channel output activity in intervals 
after it is manually activated.
z
Inactive-to-Active Delay—The channel output will remain inactive for 
the specified time interval after it is manually started.
z
Active-to-Inactive Delay—The channel output will go inactive after the 
specified time interval after it is manually started.
Default: Manual
Pulse Mode
When 
Output
 is set to 
Pulse
, you can specify the manner of the pulse.
Data Options:
z
Continuous—Continuously pulses active and inactive.
z
Count—Pulses an active/inactive sequence for the specified number of 
times.
Default: Continuous
Pulse Count
The channel output will pulse for the specified number of times; each count 
consists of an active/inactive sequence.
Default: 1
Inactive Signal 
Width
How long the channel will remain inactive during pulse mode. 
Range: 1-9999 x 100 ms
Default: 1 (100 ms)