Pertech A470e User Manual

Page of 37
A470e Users Guide
Pertech® 2006
18
Printer 
 
 
 
 
Computer
DB-9M   
 
 
 
DB-9M
Pin 
 
 
 
 
Pin
1 N/C   
 
 
 
1 N/C
2.RXD   
 
← 
 
3
3 TXD   
 
→ 
 
2
4 DTR   
 
→ 
 
6
5 SIG. GND.   
← 
 
5
6 DSR   
 
← 
 
4
   (TTL FORM IN) 
7 RTS   
 
→ 
 
8
8 CTS   
 
← 
 
7
   (TTL LOW PAPER)  → 
9. N/C   
 
 
 
N/C
The RS-232 interface uses either XON/XOFF(Software) or DTR/DSR(Hardware) protocol. This 
is set in the Configuration Mode under the serial interface selections for Flow Control for XON/
XOFF, a particular character is sent back and forth between the host computer and the printer 
to regulate the communication. For DTR/DSR, changes in the DTR/DSR signal coordinate the 
information flow.
1
2
3
4
5
6
7
8
9
The A470e printer serial interface has a DB9 Pin Male  connector. The cable must be Null Mo-
dem Serial for standard PC communications compatibility. The Baud Rate and Parity  and Flow 
Control are selectable through Command Codes or via the Configuration Mode.  The settings 
for the port on the PC must be configured the same as the printer or communication will fail.  
Flow Control
Serial Interface Pinout
DB9F to DB9F Serial 
Interface Cable 
Pertech Part Number 
106356010
RS232 Serial Interface