Chapter 5: Maintenance 
44 of 60 
 
Input Signals to Programmable Controller 
The rate monitor system has two main input signals that it uses from the extrusion process: 
the weigh hopper load cell, and the extruder speed reference. This, of course, does not include 
the operator touch-screen input. 
The extruder speed reference is generated from the supplied inductive proximity switch, or is 
wrote to the PLC through the optional Ethernet module.  
Load cells require +12 volts DC to operate. This is known as the load cell’s excitation 
voltage.  
Output Signals from Programmable Controller 
The rate monitoring system uses several output control signals to control the process. All of 
these are very similar in nature. 
The surge hopper refill solenoid is controlled by a PLC output.