Moeller Marine XControl PLC System AWB2700-1428GB User Manual

Page of 54
I
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure that devices cannot be accidentally restarted.
• Verify isolation from the supply.
• Earth and short circuit.
• Cover or enclose neighbouring units that are live.
• Follow the engineering instructions (AWA) of the 
device concerned.
• Only suitably qualified personnel in accordance with 
EN 50110-1/-2 (VDE 0105 Part 100) may work on 
this device/system.
• Before installation and before touching the device ensure 
that you are free of electrostatic charge.
• The functional earth (FE) must be connected to the protective 
earth (PE) or to the potential equalisation. The system installer 
is responsible for implementing this connection.
• Connecting cables and signal lines should be installed so 
that inductive or capacitive interference do not impair the 
automation functions.
• Install automation devices and related operating elements in 
such a way that they are well protected against unintentional 
operation.
• Suitable safety hardware and software measures should be 
implemented for the I/O interface so that a line or wire 
breakage on the signal side does not result in undefined 
states in the automation devices.
• Ensure a reliable electrical isolation of the low voltage for the 
24 volt supply. Only use power supply units complying with 
IEC 60364-4-41 (VDE 0100 Part 410) or HD 384.4.41 S2.
• Deviations of the mains voltage from the rated value must 
not exceed the tolerance limits given in the specifications, 
otherwise this may cause malfunction and dangerous 
operation.
• Emergency stop devices complying with IEC/EN 60204-1 must 
be effective in all operating modes of the automation devices. 
Unlatching the emergency-stop devices must not cause restart.
• Devices that are designed for mounting in housings or control 
cabinets must only be operated and controlled after they have 
been installed with the housing closed. Desktop or portable 
units must only be operated and controlled in enclosed 
housings.
• Measures should be taken to ensure the proper restart of 
programs interrupted after a voltage dip or failure. This should 
not cause dangerous operating states even for a short time. 
If necessary, emergency-stop devices should be implemented.
• Wherever faults in the automation system may cause 
damage to persons or property, external measures must be 
implemented to ensure a safe operating state in the event of 
a fault or malfunction (for example, by means of separate limit 
switches, mechanical interlocks etc.).
Moeller
G
mbH
Safety instructions
Warning!
Dangerous electrical voltage!